Farnesoid X receptor regulates cystathionase
...s this question. The research team led by Dr. Barbara Renga and her colleagues in the University of Perugia, Italy used luciferase transfection assay, electrophoretic Mobility Shift Assay (EMSA), Chromatin Immunoprecipitation Assay and Real-Time PCR to confirm the role of FXR in the regulation of CSE transcription. ...Mini Trans-Blot Electrophoretic Transfer Cell
Description: Includes 2 gel holder cassettes, 4 fiber pads, modular electrode assembly, Bio-Ice cooling unit, lower buffer chamber, lid with cables, and instructions. The Mini Trans-Blot cell, a component of Bio-Rad's modular mini electrophoresis system (see Mini-Vertical Electrophoresis Systems), provides rap...Trans-Blot SD Semi-Dry Electrophoretic Transfer Cell
Description: The Trans-Blot SD semi-dry transfer cell allows fast, efficient and economical blotting. Using a platinum-coated titanium plate as the anode and a stainless steel plate as the cathode, the Trans-Blot SD cell transfers in a horizontal configuration without a buffer tank or gel cassettes....High Voltage Non-Programmable Power Supplies
Description:... From SDS-PAGE to IEF to DNA sequencing, Thermo Series 90 high voltage power supplies will handle all routine electrophoretic applications. These power supplies can operate in constant voltage, constant current or constant power operating modes, with automatic crossover. To ...Certified Molecular Biology Agarose
Description:...ditional agaroses. In addition to the very low sulfate content, this produces a gel with a very high gel strength and higher exclusion limit. The high electrophoretic mobility increases resolution and reduces run time, and the gels are easy to handle even at low agarose percentages....Liposure Human Serum Lipoprotein Control
Description:... This control is specifically designed for monitoring the performance of the Lipoprint LDL electrophoretic system for separation and quantification of cholesterol in various lipoprotein fractions and subfractions in patient serum samples. Liposure is assaye...GENIE BLOTTER (Will blot gels up to 15 x 17 cm. Us
Description:... The GENIE is the proven electrophoretic transfer apparatus incorporating state-of-the-art plate electrodes for the ...eates a high field in volts/cm. The result is exceptionally rapid and exact electrophoretic transfer. ...Researchers create freestanding nanoparticle films without fillers
...hem is described in the article "Sacrificial layer electrophoretic deposition of freestanding multilayered nanopartic...tedly. They are also made using a technique called electrophoretic deposition (EPD) that is well suited for creating ...new form of EDP, which they call sacrificial layer electrophoretic deposition. They added a spun-cast layer of polyme...Biological motors sort molecules one by one on a chip
...trical field is largely dependent on the orientation of the cylinder-shaped molecules. This was the first time that this orientation-dependency of the electrophoretic mobility was observed. In an accompanying Perspective article in Science, Professor Hess of the University of Florida wrote that the Delft resear...DNA/RNA Blotting With the Trans-Blot SD Semi-Dry Electrophoretic Transfer Cell
The Trans-Blot SD DNA/RNA agarose gel support frame, used with the Trans-Blot SD semi-dry electrophoretic transfer cell, allows blotting of DNA/RNA from agarose gels to nylon membrane in minutes, without any gel pretreatments. ...Caliper Life Sciences Introduces Zephyr Genomics Workstation for Automated Liquid Handling
...customer need for automated molecular biology applications. This new workstation complements our LabChip GX system, which performs fast, automated 1-D electrophoretic separations of nucleic acid samples. Caliper also offers Sciclone, Twister, and Staccato liquid handling and integrated system solutions for higher th...Technical Note: E-PAGE(TM) 48- and 96-Well Gels on the Odyssey(R) Infrared Imaging System
...brane in as little as 40 minutes. Alternatively, a semi-dry transfer apparatus may be used for E-PAGE gel transfer, such as the Trans-Blot(R) Semi-Dry electrophoretic Transfer Cell (Bio-Rad Laboratories, Hercules, CA). Detection for blots processed in this manner can be performed using IRDye(R) Infrared Seco...'Two-Faced' Particles Act Like Tiny Submarines
...: The application of ac electric fields in aqueous suspensions of anisotropic particles leads to unbalanced liquid flows and nonlinear, induced-charge electrophoretic motion. We report experimental observations of the motion of Janus microparticles with one dielectric and one metal-coated hemisphere induced by unifo...High Throughput Plasmid DNA Preparation Using A Magnetic Bead Kit On An Automated Workstation
...ut of 384 samplings (4 x 96 well plates). Nucleic acid yield for the two systems are roughly 16 ng/μL by PicoGreen binding analysis. Results from electrophoretic separation of the purified nucleic acid are presented in Figure 2. Discussion The Agencourt CosMCPrep Kit... Protein blotting and fluorescent detection
After electrophoretic separation the gels were blotted onto either Hybond ECL (low-fluorescent nitrocellulose) or Hybond-LFP (low-fluorescent PVDF) membranes for 2.5 h at 2...
LIGHTSHIFT EMSA Kit from Pierce Biotechnology, Inc.
Description:... The electrophoretic mobility shift assay (EMSA) is a powerful tool for evaluating DNA-protein i...d oligos from custom oligo suppliers Sensitive, fast and non-radioactive electrophoretic mobility shift assays...ProteoExtract Protein Precipitation Kit from Calbiochem
Description:...e analysis is often hampered by the presence of non-protein impurities such as buffers, salts and detergents in the protein sample that interfere with electrophoretic separations or enzymatic digestion. Additionally, proteins in solutions are often too dilute for direct downstream applications such as 2DGE. Precipit...Mini Trans-Blot and PowerPac Basic Power Supply from Bio-Rad
Description:... The Mini Trans-Blot cell and PowerPac Basic power supply are used for electrophoretic blotting from gels to membranes. The Mini Trans-Blot cell accommodates two 7.5 x 10 cm gels and includes 2 gel holder cassettes, modular electrode ass...The Discovery Series PDQuest Version Upgrade from Bio-Rad
Description:... The Discovery Series PDQuest 2-D analysis software is used for imaging, analyzing, and databasing two-dimensional electrophoretic gels. The version upgrade allows upgrade of an established version of the PDQuest software to the newest version....PDQuest 10-User Network License from Bio-Rad
Description:... The Discovery Series PDQuest 2-D analysis software is used for imaging, analyzing, and databasing two-dimensional electrophoretic gels. The 10-user network license entitles ten users to access data from a server....2% Bis Solution, 500 ml from Bio-Rad
Description:... Bis-Acrylamide (bis) is a monomer used as a crosslinker with acrylamide to form polyacrylamide electrophoretic gels. This 2% bis solution is supplied as 500 ml....Stirbar, Trans-Blot Plus cell from Bio-Rad
Description:... The stirbar is used in the buffer tank of the Trans-Blot Plus cell to maintain uniform conductivity and temperature during electrophoretic transfer. Dimensions are 3.5 x 0.5 in....Super Cooling Coil, Trans-Blot cell from Bio-Rad
Description:... The super cooling coil, Trans-Blot cell, provides temperature regulation for native enzyme, high-intensity, and extended electrophoretic transfer (blotting) applications performed with the Trans-Blot cell. Use of the super cooling coil requires connection to an external water recirculat...ATTO-TAG CBQCA Amine-Derivatization Kit from Molecular Probes (Invitrogen)
Description:...CBQCA 1) and ATTO-TAG FQ (3-(2-furoyl) quinoline-2-carboxaldehyde 2) react specifically with primary amines to form conjugates that can be analyzed by electrophoretic or chromatographic methods. Unlike OPA and NDA, ATTO-TAG CBQCA will also react with hydrophilic peptides and amino sugars. The resulting products of C...