SURGIWIPtrade; Suture Ligature with POLYSORBtrade;
Description: The SURGIWIP™ suture ligature with delivery system is indicated for use in gynecologic, general and other abdominal and thoracic endoscopic procedures where a suture is appropriate for the endoscopic approximation and ligation of soft tissues....SURGIWIPtrade; Suture Ligature with SURGIDACtrade;
Description: The SURGIWIP™ suture ligature with delivery system is indicated for use in gynecologic, general and other abdominal and thoracic endoscopic procedures where a suture is appropriate for the endoscopic approximation and ligation of soft tissues....ENDOLOOP Ligature Type - 0 Plain Gut ligature
Description: The ENDOLOOP consists of 18'' long ligature inserted into a plastic tube. The plastic tube is narrow at one end and scored on the other. The suture protrudes from the narrow end and is formed in a ligature loop with a knot which becomes secure after the device is activated. The opposite end of the ...ENDOLOOP Ligature Type - 0 PDSII ligature
Description: The ENDOLOOP consists of 18'' long ligature inserted into a plastic tube. The plastic tube is narrow at one end and scored on the other. The suture protrudes from the narrow end and is formed in a ligature loop with a knot which becomes secure after the device is activated. The opposite end of the ...ENDOLOOP Ligature Type - 0 Coated VICRYL®
Description: The ENDOLOOP consists of 18'' long ligature inserted into a plastic tube. The plastic tube is narrow at one end and scored on the other. The suture protrudes from the narrow end and is formed in a ligature loop with a knot which becomes secure after the device is activated. The opposite end of the ...ENDOLOOP Ligature Type - 0 Chromic Gut
Description: The ENDOLOOP consists of 18'' long ligature inserted into a plastic tube. The plastic tube is narrow at one end and scored on the other. The suture protrudes from the narrow end and is formed in a ligature loop with a knot which becomes secure after the device is activated. The opposite end of the ...ENDOLOOP Ligature Type - 0 Chromic Gut ligature with Introducer
Description: The ENDOLOOP consists of 18'' long ligature inserted into a plastic tube. The plastic tube is narrow at one end and scored on the other. The suture protrudes from the narrow end and is formed in a ligature loop with a knot which becomes secure after the device is activated. The opposite end of the ...POLY SURGICLIP™ (Single Use Automatic Clip Applier With Absorbable Clips)
Description:...; POLY SURGICLIP™ disposable automatic clip applier has application in many types of surgical procedures where an absorbable or radiotransparent ligature is indicated or desired....Endoavitene Preloaded Applications
Description:... Avitene Microfibrillar Collagen (MCH) is used in surgical procedures as an adjunct to hemostasis when control of bleeding by ligature or conventional procedures is ineffective or impractical....Avitene Sheets (Non-Woven Web)
Description:... Avitene Microfibrillar Collagen Hemostat (MCH) is used in surgical procedures as an to hemostasis when control of bleeding by ligature or conventional procedures is ineffective or impractical....Pressure Ridge Double Plate Molteno Implant (DR2/DL2)
Description:...aocular muscles. Choice of left or right eye configurations. Insertion is well described and straightforward. The surgeon may select from a variety of ligature or stent procedures to improve the control of postoperative hypotony and bleb fibrosis....Double Plate Molteno Implant (R2/L2)
Description:...aocular muscles. Choice of left or right eye configurations. Insertion is well described and straightforward. The surgeon may select from a variety of ligature or stent procedures to improve the control of postoperative hypotony and bleb fibrosis....Microphthalmic Plate Molteno Implant (M1)
Description:...aocular muscles. Choice of left or right eye configurations. Insertion is well described and straightforward. The surgeon may select from a variety of ligature or stent procedures to improve the control of postoperative hypotony and bleb fibrosis....Pressure Ridge Single Plate Molteno Implant (D1)
Description:...aocular muscles. Choice of left or right eye configurations. Insertion is well described and straightforward. The surgeon may select from a variety of ligature or stent procedures to improve the control of postoperative hypotony and bleb fibrosis....Single Plate Molteno Implant (S1)
Description:...aocular muscles. Choice of left or right eye configurations. Insertion is well described and straightforward. The surgeon may select from a variety of ligature or stent procedures to improve the control of postoperative hypotony and bleb fibrosis....Ahmed™ Glaucoma Valve Bi-Plate
Features:... Eliminates drainage tube ligature sutures, "rip-chord sutures, occluding sutures. Attachable on either right or left side. Bi-Plate design allows for greater aqueous drainage. Valve an...Ahmed Glaucoma Valve (small size)
Features:...ue non-obstructive valve system to prevent excessive drainage, chamber collapse. Implanted in a true, single-stage procedure. Eliminates drainage tube ligature sutures, "rip-chord" sutures, occluding suture. Used for Pediatrics or small globes....