96 well plate shaker, 220 V from Mo Bio Laboratories, Inc.
Description:... Disrupts biological cells for DNA isolation. Designed to hold two 96 well plates (includes 96 well plate adapters from Mo Bio). Provides consistent lysis across the entire plate length (max capacity is 192 indivi...HT96 Isothermal Block from Novagen
Description:...lock is an anodized aluminum, solvent-resistant block specially designed to hold HT96 plates and to provide efficient thermal transfer to samples within the...lock is an anodized aluminum, solvent-resistant block specially designed to hold HT96 plates and provide efficient thermal transfer to samples within the 96...Mechanical Cell Strain Instrument STREX ST-140-04 from B-Bridge International
Description:... Automated instrument designed to hold up to 6 strain chambers with precise uniaxial mechanical strain. The robust and easy to use design ensures that cells grow over long periods of time w...Nanoject II, 220 VOLT from Drummond Scientific Company
Description:...gher torque motor. This new motor is quieter and smoother in operation further reducing tip movement. The development of new collet configuration will hold the micropipet more securely and thereby reduce air infiltration and oil leakage. The two speed fill/inject mode will allow the user to fill and injec...Dyad Disciple Thermal Cycler Chassis from Bio-Rad
Description:...erated independently, using a PC. The Dyad Disciple accommodates a variety of interchangeable Alpha units (sample-holder, heat-pump assemblies), which hold different types vessels, as well as the Chromo4 real-time detector. Peltier heat pumps provide exceptional thermal performance. Temperature gradient c...Tube Rotator from Barloworld Scientific Ltd
Description:... Rotator, variable speed, timer, SB3 Fully adjustable mixing angle Variable speed Digital timer Choice of tube holders to hold a number of different sized tubes Spillage tray The SB3 is ideal for aerating cultures, keeping biological samples in suspension and for gene...DNA Engine Tetrad 2 Thermal Cycler Chassis from Bio-Rad
Description:... The four-bay DNA Engine Tetrad 2 thermal cycler accommodates a variety of interchangeable Alpha units (sample-holder, heat-pump assemblies), which hold different types and numbers of vessels. A Pentium-class computer drives an advanced graphical interface that displays current block, sample, and lid t...GeNunc Tube Tray and Holder from Sigma-Aldrich
Description:... General description: Workstation for PCR set-up Easy to assemble Standard 96 MicroWell format to hold 0.2 ml PCR tubes, strips or Nunc 96 Well Amplifications Plate compatible with automated handling systems Removable tray can be fitted directly int...GenElute Agarose Spin Columns from Sigma-Aldrich
Description:...band is excised from an agarose gel and loaded into the spin column. Embedded within the base of the column are a series of membranes and filters that hold agarose and impurities back while allowing DNA to selectively pass through the column into a collection tube during a 10 minute centrifugation. GenElu...GenElute Minus EtBr Spin Column from Sigma-Aldrich
Description:...band is excised from an agarose gel and loaded into the spin column. Embedded within the base of the column are a series of membranes and filters that hold agarose and ethidium bromide back while allowing DNA to selectively pass through the column into a collection tube during a 10 minute centrifugation. ...Vivaclear Centrifugal Filters from Sartorius AG
Description:...y can be used in fixed angle rotors accepting 2.2 ml centrifuge tubes. Product Features: High-flux Polyethersulphonemembrane 0.8 m pore size Low hold up volume ( Fast and reproducible performance Applications: Clarification of samples before loading onto Vivapure protein purification spin column...CORNING HYBRIDIZATION CHAMBER,25MMX75M from Sigma-Aldrich
Description:... General description: Humidity wells in the base hold 10 l of water to maintain chamber humidity and probe hydration around the edges of the coverslip. The watertight seal eliminates the risk of waterbath...cGMP Safe Deposit Facility from European Collection of Cell Cultures (ECACC)
Description:...ge Conditions: Cell lines are stored in vapour phase above a liquid nitrogen reservoir. The ampoules are placed within an aluminium cryo-box that can hold up to 100 ampoules. The depositor can request to have separate cryo-boxes for each cell line deposited or multiple deposits in one cryo-box. Cryo-boxe...PAP Pen from ScyTek Laboratories
Description:...esigned to provide a thin film-like barrier when a circle is drawn around the specimen on a slide. This barrier creates the proper surface tension to hold an antibody solution within the target area on the slide. PAP Pen contains a special formulation which is insoluble in alcohol and acetone. It can b...DNA Engine Dyad Thermal Cycler Chassis from Bio-Rad
Description:...e platform for DNA amplification (PCR). The chassis accommodates a variety of interchangeable Alpha units (sample-holder, heat-pump assemblies), which hold different types and numbers of vessels. Color display offers graphical programming with point-and-click navigation. Peltier heat pumps, built in-house...Econo Gradient Pump Rack, preassembled from Bio-Rad
Description:... The Econo gradient pump rack is a preassembled rack that is used to hold the components of the Econo gradient pump kits....Sample Holders, for gels from Bio-Rad
Description:... The sample holders for gels are used to hold gels in place in the multi-sample tray I, which is used with Molecular Imager FX imaging systems....Trans-Blot Plus Gel and Cassette Assembly Tray from Bio-Rad
Description:... The Trans-Blot Plus gel and cassette assembly tray is used to hold the Trans-Blot Plus gel holder cassette, buffer, and other materials for the gel and membrane sandwich during their assembly....Hyb-Seal Slide Chambers, 20 x 63 mm, pkg of 100 from Bio-Rad
Description:...n sealed with plastic sealing dots. Dots can be removed and replaced to allow exchange of reaction fluid. These chambers enclose a 20 x 63 mm area and hold 465 microliters. Each package contains 100 chambers and 200 sealing dots....2800ml Flask Clip from Thermo Scientific
Description:...event scratching of expensive glassware. Clips include the required mounting screws. Microplate clip is a one-piece, stainless steel plate that can hold a single shallow or deep well microplate...250/300ml Flask Clip from Thermo Scientific
Description:...event scratching of expensive glassware. Clips include the required mounting screws. Microplate clip is a one-piece, stainless steel plate that can hold a single shallow or deep well microplate...1 Liter Flask Clip from Thermo Scientific
Description:...event scratching of expensive glassware. Clips include the required mounting screws. Microplate clip is a one-piece, stainless steel plate that can hold a single shallow or deep well microplate...Sterile infusion kit, standard configuration from Instech Solomon
Description:...livery times are 1-2 weeks from receipt of order. With a pattern of regular orders and good communication about upcoming studies, Instech Solomon will hold a stock of your kits to cut lead times even further. The standard minimum order quantity is 25 kits. This minimum is waived on initial trial orders. T...GyroTwister GX-1000 3-D Shaker from MIDSCI
Description:... gels, hybridization and other applications. Shaking speed is continuously adjustable across a broad range. A nonslip rubber mat and elastic tie-downs hold samples in place during operation. A dimpled mat is included for holding tubes in place. Larger platforms and a stacked standard platform configuratio...FAST Frame Multiple Slide Plate from Whatman, Inc
Description:... High Throughput Processing of Microarrays Using the New FAST(tm) Frame Multi-Slide Plate! FAST Frame multiple slide plate is designed to hold four, 16-pad FAST Slides and the corresponding multi-well incubation chambers in a microplate footprint for high throughput processing of microarrays....