* Quick & Easy Conditional Knock Out Kit - FRT from Gene Bridges GmbH
Description: This kit is designed for the fast and simple integration of FRT-sites into large vector plasmids at any position (for the generation of transgenic mouse models). The included FRT-PGK-gb2-neo-FRT cassette is designed to allow neomycin / kanamycin selection in prokaryotic and eukaryotic cells. It com...* Quick & Easy Conditional Knock Out Kit - loxP from Gene Bridges GmbH
Description: This kit is designed for the fast and simple integration of loxP-sites into large vector plasmids at any position (for the generation of transgenic mouse models). The included loxP-PGK-gb2-neo-loxP cassette is designed to allow neomycin / kanamycin selection in prokaryotic and eukaryotic cells. It ...DUALmembrane 3 kit from Dualsystems Biotech AG
Description:... Use the DUALmembrane kit 3 to carry out DUALmembrane interaction analysis and cDNA library screening to characterize interactions between integral membrane proteins and to identify novel int...Cy3 Ab Labeling Kit from GE Healthcare, formerly Amersham Biosciences
Description:... Cy3 Ab Labeling Kit, 1 kit. Convenient way to tag antibodies with CyDye fluorescent dyes. Conjugations are carried out under mild conditions and are complete within 1 h. Dyes are packaged in premeasured amounts and foil sealed to ensure consistent labelings. Category...Essential Data: Centrifugation from Promega
Description:... Edited by D. Rickwood, T.C. Ford and J.T. Steensgaard (1994) Compiles core data required by researchers carrying out any centrifugal separation, whether working with cells, organelles or macromolecules....N-terminal Sequencing from Primm Biotech, Inc.
Description:...blotted protein on PVDF membrane or with protein in solution (preferably in water) The N-terminal sequence of proteins (5-20 residues) can be carried out on samples purified by HPLC or mono-and bidimensional SDS-PAGE, followed by electroblotting on PVDF (Polyvinylidene difluoride) membranes using the we...Silencer Pre-designed siRNA, HPLC purified, annealed from Ambion
Description:...can be readily ordered online by providing either the 19-21 base target sequence, or by providing the sense and antisense siRNA sequences. (Also check out Ambion's Silencer Validated and Silencer Pre-designed siRNAs, which are already designed for you.) For your convenience, siRNAs are provided in variou...Silencer Pre-designed siRNA, standard purity from Ambion
Description:...can be readily ordered online by providing either the 19-21 base target sequence, or by providing the sense and antisense siRNA sequences. (Also check out Ambion's Silencer Validated and Silencer Pre-designed siRNAs, which are already designed for you.) For your convenience, siRNAs are provided in variou...Custom siRNA, PAGE purified from Ambion
Description:...can be readily ordered online by providing either the 19-21 base target sequence, or by providing the sense and antisense siRNA sequences. (Also check out Ambion's Silencer Validated and Silencer Pre-designed siRNAs, which are already designed for you.) For your convenience, siRNAs are provided i...Silencer Pre-designed siRNA, HPLC purified from Ambion
Description:...can be readily ordered online by providing either the 19-21 base target sequence, or by providing the sense and antisense siRNA sequences. (Also check out Ambion's Silencer Validated and Silencer Pre-designed siRNAs, which are already designed for you.) For your convenience, siRNAs are provided in variou...Custom siRNA, PAGE purified, annealed from Ambion
Description:...can be readily ordered online by providing either the 19-21 base target sequence, or by providing the sense and antisense siRNA sequences. (Also check out Ambion's Silencer Validated and Silencer Pre-designed siRNAs, which are already designed for you.) For your convenience, siRNAs are provided i...Autotrace SPE Workstation from Caliper Life Sciences
Description:...much as ten-fold when converting from a liquid/liquid extraction method Greatly reduces labor requirement, affording more time for analysts to carry out method development, sample analysis, and data interpretation. Improves overall data quality and reproducibility through consistent sample handling ...Adept HPLC System 6, Automatic Binary Gradient from Cecil Instruments Ltd.
Description:... Analysis of large numbers of samples may be carried out using this high pressure gradient system, which requires minimum operator attention. System control and data processing is provided by PowerStream ...General DNA Sequencing Services from Polymorphic DNA Technologies, Inc.
Description:...lease provide 15 μL of product at a concentration of .02 μg/μL to .05 μg/μL. Please also send a photo of the PCR products run out on an agarose gel. Primers should be provided at 5 μM with at least 10 μL volume....Adept HPLC System 3, Automatic Isocratic from Cecil Instruments Ltd.
Description:... Analysis of large numbers of samples may be carried out using this high pressure system which requires minimum operator attention. System control and data processing is provided by PowerStream software a...Adept HPLC System 3S, Automatic Isocratic from Cecil Instruments Ltd.
Description:... Analysis of large numbers of samples may be carried out using this high pressure system which requires minimum operator attention. System control and data processing is provided by PowerStream software and...Prelude Workstation from Caliper Life Sciences
Description:...es that have Prelude Improved lab cycle time 21CFR11 compliant operating system provides secure data Audit trail helps make the investigation of out of specification results more efficient. ...Hybridization Cassettes from Caliper Life Sciences
Description:...w volume chamber (67uL analytical cavity volume) eliminates the need for cover slips. Not only does the Hybridization Cassette make it easier to carry out microarray hybridizations, but also it has demonstrated the ability to greatly improve the quality and consistency of microarray results. While design...FAM Poly Caspase Assay Kit from B-Bridge International
Description:...D-FMK FLICA reagent becomes covalently coupled to the enzyme, it is retained within the cell, while any unbound FAM-VAD-FMK FLICA reagent will diffuse out of the cell and is washed away. The remaining green fluorescent signal is a direct measure of the number of active caspase enzymes that were present ...Freeze 'N Squeeze Spin Columns, 25 from Bio-Rad
Description:... Freeze 'N Squeeze DNA gel extraction spin columns use a quick freeze-and-thaw cycle and centrifugation to draw 50-23,000 bp DNA out of agarose gel slices. Supplied as 25 columns....Freeze 'N Squeeze Spin Columns, 100 from Bio-Rad
Description:... The Freeze 'N Squeeze DNA gel extraction kit uses a quick freeze-and-thaw cycle and centrifugation to draw 50-23,000 bp DNA out of agarose gel slices. The kit includes materials for 100 preps....GeneTraffic from Iobion Informatics
Description:... reliable Open Source foundation: LINUX, the R statistical language, PostgreSQL, and Apache Web server. GeneTraffic software creates a LINUX Appliance out of an affordable off-the shelf workstation computer. This approach keeps the cost of the software down and support and maintenance issues low. You can...Human 25-Hydroxy Vitamin D EIA Kit from IDS Ltd
Description:... and therefore facilitates automation on many ELISA processors. The kit enables the smaller laboratory to process samples manually rather than sending out to larger labs, with the associated indeterminate turn around time. It also permits the larger laboratory to automate 25-OH D on an open system....Rabbit Anti-PLAU N-term RB4087 Polyclonal Antibody, Unconjugated from Abgent
Description:...AU. Purified rabbit polyclonal antibody supplied in PBS with 0.09% (W/V) sodium azide. This antibody is purified through a protein G column and eluted out with both high and low pH buffers and neutralized immediately after elution then followed by dialysis against PBS....prOTOF 2000 MALDI O-TOF Mass Spectrometer from PerkinElmer
Description:...crepancies that are associated with the ionization of the sample and/or the sample target (the substrate on which the sample is deposited) are carried out to the detector. This can affect instrument performance in the areas of accuracy, resolution, and sensitivity....EasyCode Windows Software from AutoMate Scientific, Inc
Description:...off sequences with a PC computer running Windows 98, 2000, XP using graphic 'click-and-drag' timebars. Save and load unlimited programs to disk, print out program listings, then download your programs into the ValveBank's memory in one simple step. EasyCode is used for programming before -- not dur...EasyCode Macintosh Software from AutoMate Scientific, Inc
Description:...your valve and TTL on-off sequences with a Macintosh computer using graphic 'click-and-drag' timebars. Save and load unlimited programs to disk, print out program listings, then download your programs into the ValveBank's memory in one simple step. EasyCode is used for programming before -- not dur...MSC.12 class II safety cabinet (Type A1) - CE Marked (230V / 50Hz) from Thermo Scientific
Description:... working conditions and certification to the world's highest safety standards. Fully automatic regulation ensures that the cabinets cannot be adjusted out of safe working conditions. Natural lighting, low noise and arm rest ensure safety through comfort....MSC.12 class II safety cabinet (Type A1) - CE Marked (120V / 60Hz) from Thermo Scientific
Description:... working conditions and certification to the world's highest safety standards. Fully automatic regulation ensures that the cabinets cannot be adjusted out of safe working conditions. Natural lighting, low noise and arm rest ensure safety through comfort....Xcise automated robotic system for Gel Processing from Shimadzu Biotech
Description:...is a powerful technology platform that automates gel processing for high throughput proteome analysis. High quality sample preparation can be carried out by an untrained user. The Xcise is a powerful technology platform that automates gel processing for high throughput proteome analysis. It combines...HERAsafe KS from Thermo Scientific
Description:...d from a seated position. No need to strain your back when you want to find out the current operating status of your cabinet. For the first time, all par... area the remote control can be used with a bag. No need to take your hands out of the clean air atmosphere when you want to change the settings of your ca...KingFisher magnetic particle processor (100-240 V) from Thermo Scientific
Description:...s from 20 - 1000 l. Each system consists of an instrument, specially designed plastics and software. In KingFisher, all purification steps are carried out in microplates. Working volume is 20-200 l. 24 samples per run can be purified....CaspaTag™ Pan-Caspase In Situ Assay Kit, Fluorescein from CHEMICON
Description:...erodimer, thereby inhibiting further enzymatic activity. The bound labeled reagent is retained within the cell, while any unbound reagent will diffuse out of the cell and is washed away. The green fluorescent signal is a direct measure of the amount of active caspase present in the cell at the time the r...CaspaTag™ Pan-Caspase In Situ Assay Kit, Sulforhodamine from CHEMICON
Description:...erodimer, thereby inhibiting further enzymatic activity. The bound labeled reagent is retained within the cell, while any unbound reagent will diffuse out of the cell and is washed away. The red fluorescent signal is a direct measure of the amount of active caspase present in the cell at the time the rea...