F-7000 Research Grade Fluorescence Spectrophotometer from Hitachi High Technologies America
Description:The F-7000 is a research grade spectrofluorometer which offers high sensitivity, variable spectral bandwidth and scanning speeds of up to 60,000nm/min. Its horizontal beam optical design provides a high concentrated light beam along with low sample volume requirements. It works with our FL Solutions, PC fluorescence applications software, which offers Excitation/Emission Scan, Time Based Measur...Dulbecco's Modified Eagle's Medium - high glucose (DME) from Sigma-Aldrich
Description:Many modifications of Eagle's medium have been developed since the original formulation. The most widely used modification is Dulbecco's Modified Eagle'sMedium. DME is a modification of Minimum Essential Medium Eagle [MEM] that contains a higher concentration of vitamins and amino acids, as well asadditional supplementary components....LXQ High Throughput Linear Ion Trap from Thermo Scientific
Description:The LXQ linear ion trap mass spectrometer enables high-throughput solutions for todays fast paced analytical laboratory. The LXQ linear ion trap mass spectrometer is designed for drug discovery and proteomic applications, delivering the fast cycle time and increased sensitivity of a Thermo linear ion trap at an attractive price. The combination of fast cycle time and high MS n spectral qual...NanoFrontier LD LC/MS System from Hitachi High Technologies America
Description:Hitachi Innovative Linear Ion Trap Time of Flight Mass Analyzer for superior sensitivity, mass accuracy, and resolving power. Specifications: * MS mode measurement range: 100 - 25,000 m/z * Precursor ion selection range: 150 - 4000 m/z * Resolution: 14,000 (1400 m/z) or over * MS accuracy: 5 ppm with internal reference * Dynamic range: 4 orders of magnitude...Catch & Release v2.0 High Throughput (HT) Immunoprecipitation Assay Kit- 96 well from Upstate
Description:This kit allows for quick and reproducible immunoprecipitation (IP) by using a 96 well filter plate. The system is more reproducible than regular IPs, which are problematic with regards to washing the protein A/G agarose without disrupting the agarose bed. The binding of the antibody/antigen complex in Catch and Release is reversible, and elution of the immune complex can occur with native or den...Expand High Fidelity PCR System, dNTPack (Not available in US) from Roche Applied Science
Description:...Expand High Fidelity PLUS PCR System; Thermostable DNA polymerase mixture from Roche Applied Science
Description:Roche Applied Science, which pioneered the blending of thermostable DNA polymerases with the Expand High Fidelity and Expand Long Template PCR Systems, now introduces the Expand High FidelityPLUS PCR System the first product of a family of next-generation PCR Blends. This new blend combines Taq DNA Polymerase with a novel proofreading protein isolated and characterized by Roche Applied Sc...7 boxes per rack, 3" high, cardboard from Thermo Scientific
Description:Thermo Forma provides an array of accessory Racks for the Cryo/CryoPlus 16" Diameter storage system. To maximise inventory capacity a Jumbo Arrowhead configuration is recommended. You may choose between Cardboard or Stainless Steel boxes....FastStart High Fidelity PCR System, dNTPack (Not available in US) from Roche Applied Science
Description:...Thermal paper, high gloss, 5 rolls (1000 images) from UVP
Description:Request Info...Sma I (High Concentration) from Takara Mirus Bio
Description:...Hae III (High Concentration) from Takara Mirus Bio
Description:Request Info...Macro-Prep High Q Support, 500 ml from Bio-Rad
Description:Macro-Prep ion exchange media are rigid macroporous hydrophilic media. The rigid polymer matrix allows high flow rates at moderate pressures, while the macroporous beads enhance access to ionic sites, and the hydrophilic matrix reduces nonspecific binding. Macro-Prep High Q support is a high-capacity strong anion exchanger with very high flow rates and resolution. It has Cl- as the counterion; no...Biomek FX Laboratory Workstation (High Throughput) from Beckman Coulter
Description:The Biomek FX provides complete solutions for high-throughput genetic analysis applications. With 96-, 384-, and independent 8- channel pipetting heads in either single or dual arm configurations, the Biomek FX offers maximum speed and flexibility for nucleic acid preparation....GIBCO Dulbeccos Modified Eagle Medium (D-MEM); powder (high glucose) from Invitrogen
Description:...Target Retrieval Solution, High pH, Concentrated x 10 from Dako
Description:Target Retrieval Solution, High pH, Concentrated x 10 This pH 9.9 solution is intended for heat-induced target retrievel prior to immunohistochemical staining procedures. It is for use on formalin-fixed, paraffin-embedded tissue sections mounted on glass slides. For particular antigens, target retrieval at high pH, 9.9, is especially effective. It should be noted that also endogenous bioti...Target Retrieval Solution, High pH from Dako
Description:Target Retrieval Solution, High pH This pH 9.9 solution is intended for heat-induced target retrievel prior to immunohistochemical staining procedures. It is for use on formalin-fixed, paraffin-embedded tissue sections mounted on glass slides. For particular antigens, target retrieval at high pH, 9.9, is especially effective. It should be noted that also endogenous biotin is effectively de...CORNING 96 WELL EIA/RIA MICROPLATE,R-BOTTOM,HIGH BINDING,NON STERILE,W/O LID from Sigma-Aldrich
Description:Designed for in vitro diagnostic assays, all EIA/RIA plates are manufactured from special medical-grade polystyrene for uniform binding, high optical clarity and low background absorption. In addition, the Easy-Washproducts are part of the Certified Surface Chemistry Programme, which guaarantees protein binding performance to be within QA release specifications. Linkage: This CLS number is a n...CORNING 96 WELL PLATE, EIA/RIA, PS, ROUND BOTTOM, HIGH BINDING, NON STERILE from Sigma-Aldrich
Description:Not treated (or medium binding) polystyrene surface is hydrophobic in nature and binds biomolecules through passive interactions• Is suitable primarily for the immobilization of large molecules, such as antibodies, that have large hydrophobic regions that can interact with the surface• Binding capacity of approximately 250 ng of mouse IgG/cm2• EIA/RIA plates are tested on lot-to...TiterHigh Sf Insect Medium from Sigma-Aldrich
Description:Designed to meet the needs of the biopharmaceutical industry, this animal component-free medium supports fast cell growth rates and high cell densities, while maintaining high cell viability and high recombinant protein production using the Baculovirus Expression Vector System (BEVS). Sterile, Cell culture tested...Experion RNA HighSens Analysis Kit for 25 Chips from Bio-Rad
Description:The Experion HighSens analysis kit for 25 chips provides the chips and reagents required to perform high-sensitivity RNA analysis (at picogram levels) with the Experion automated electrophoresis system. This kit includes 25 RNA HighSens microfluidic chips, 2 x 1,250 microliters RNA gel, 2 x 20 microliters RNA HighSens stain, 20 microliters RNA ladder, 2 x 900 microliters RNA HighSens loading buff...Experion RNA HighSens Reagents and Supplies, for 10 chips from Bio-Rad
Description:Experion HighSens reagents and supplies, for 10 chips, provides the reagents and supplies sufficient to perform high-sensitivity RNA analysis (picogram levels) with 10 chips on the Experion automated electrophoresis system. Supplied are 1,250 microliters RNA gel, 20 microliters RNA HighSens stain, 20 microliters RNA ladder, 900 microliters RNA HighSens loading buffer, 100 microliters RNA sensitiv...High Temperature miniDAWN (HTmD) for 150C, PL220C, Alliance 2000 from Wyatt Technology
Description:The newest member of Wyatt Technology's family of light scattering instruments. The HTmD fits inside of your high temperature chromatograph and enables you to get multi-angle light scattering data from thermoplastic polymers. The HTmD is easily installed in the oven of any Waters 150C, PL220C or Alliance 2000 device and enables you to get three angles of light scattering data taken simultaneously...High-Throughput Fluidics System from Bio-Rad
Description:The high-throughput fluidics (HTF) system, 100-240 V, is an optional module for the Bio-Plex suspension array system that automates delivery of up to 20 L of sheath fluid into the Bio-Plex array reader. The HTF system automatically draws sheath fluid from a nonpressurized bulk sheath container to constantly maintain a reservoir of pressurized sheath fluid. A single 20 L sheath fluid container pro...Bio-Plex Suspension Array System, with high-throughput fluidics (HTF) system from Bio-Rad
Description:The Bio-Plex suspension array system, 100-240 V, uses xMAP technology for simultaneous quantitative analysis of up to 100 proteins and peptides in one microplate well. The suspension array is composed of up to 100 color-coded bead sets, each of which may be conjugated with a unique reactant (enzyme substrates, receptors, antigens, or antibodies) specific to a given target. This system includes an...Biomek FX Laboratory Workstation (High Throughput) from Beckman Coulter
Description:...High Pressure Dual Piston Analytical Pump from Cecil Instruments Ltd.
Description:The new Adept CE 4100 with stepper motor drive, provides superb flow precision, with software drive compensation, reducing pulsing to negligible levels. Flow rates from 0.001-10mL/min are selectable in 0.001mL steps. The pump heads, using ceramic inserts, are inert and bio-compatible. Pumps may be programmed from their keypad, using the 4 line LCD display of...Experion RNA HighSens Chips, 10 from Bio-Rad
Description:Experion HighSens chips are the microfluidic chips used to perform high-sensitivity RNA analysis (picogram levels) with the Experion automated electrophoresis system. Each chip has the capacity to run 11 RNA samples. Supplied as 10 chips....High Five Cells SFM Adapted from Invitrogen
Description:High Five cells (BTI-TN-5B1-4) derived from Trichoplusia ni egg cell homogenates have been shown to be capable of expressing significantly higher levels of secreted recombinant proteins compared to other insect cells. High Five cells offer the following features:- -Rapid doubling time as adherent cultures- Quick adaptation into serum-free medium- Up to 25-fold higher expression of secreted protei...Streptavidin Sepharose High Performance from GE Healthcare, formerly Amersham Biosciences
Description:Streptavidin Sepharose High Performance, 5 ml. The same high performance streptavidin media used in HiTrap Streptavidin columns for fast, reliable purification of biotinylated compounds.Ideal for packing into Tricorn 5/50 GL, XK 16/20, or other columns when larger scale purifications are required.Extremely useful for exploiting either the strong interactions of biotin and streptavidin or the some...GeneAmp High Fidelity PCR from Applied Biosystems
Description:PCR System for increased fidelity, yield and length of PCR products. Amplifies targets up to 10 kb from human genomic DNA....E-Gel96 High-Throughput Agarose Electrophoresis System from Invitrogen
Description:Turn routine agarose gel electrophoresis into an automated, high-throughput operation with the E-Gel 96 system. This bufferless, pre-cast system is ideal for analyzing multiple PCR products, plasmid preparations, restriction digests, and more. Fully automated, robot-compatible, and ready to put into action, the E-Gel 96 system makes your high-throughput screening assignments as easy as Plug & Pla...High Molecular Weight DNA Markers from Invitrogen
Description:High Molecular Weight DNA Markers are suitable for sizing linear double-stranded DNA from 9 to 48 kb on low-percentage agarose gels. The 13 bands consist of 8.3- to 48.5-kb fragments generated from restriction endonuclease digests of Lambda DNA (cIind1ts857 Sam7). Ethidium bromide staining causes the four bands identified by an asterisk (8271 bp 8612 bp 12220 bp and 19399 bp) to show greater inte...Cultrex High Protein Concentration BME from Trevigen
Description:Cultrex High Protein Concentration Basement Membrane Extract Cultrex HC20+ was developed for use in in vivo applications where higher protein concentrations facilitate faster gelling times, increased gel strength, and elevated levels of tumor augmentation. Cultrex HC20+ has the advantage of lot-to-lot consistency and controlled protein concentrations to support in vivo angiogenesis assays and t...High-Binding EIA 96 Well Strip Plates from Cayman Chemical
Description:Request Info...High-Binding EIA 96 Well Plates from Cayman Chemical
Description:Request Info...High-Binding EIA 96 Well Plates from Cayman Chemical
Description:Request Info...Agarose, high EEO, Molecular Biology Grade from Research Organics, Inc.
Description:...