The Sabet Lenticular Safety Net
Description:...
Provides The Length Of A Cyclodialysis Spatula To Reach Into The
vitreous Cavity To Salvage Lens Fragments With One Instrument.
A 23g ... For Fragment Support.
Thin And Sturdy Wires Minimize Traction In The
vitreous While Supporting A ....
Company:Rhein Medical, Inc.
Healon
Description:... tissues in both animals and man. For example, it is present in the
vitreous and aqueous humor of the eye, the synovial fluid, the skin and the ... developed as an ophthalmo-surgical aid for use in anterior segment and
vitreous ....
Company:Advanced Medical Optics, Inc.
MembraneBlue
Description:... the I.L.M. and E.R.M.'s. By injecting Membraneblue in an air-filled
vitreous cavity, the intraocular membranes are stained without diluting the dye. ... be distinguished from the underlying, unstained retina after refilling the
vitreous cavity with fluid. (MBB-05 MembraneBlue,Sterile, 5 vials / 0,5ml. Patent ...
Company:Dutch Ophthalmic, USA
Direct Image Flat SSV®
Description:... The Chalam Flat is designed for routine vitrectomy, optic nerve neurotomy and induction of posterior
vitreous detachments. It is also useful for macula whole surgery, epiretinal membranes and for removal of tractional epiretinal membranes. Direct image lens ...
Company:Volk Optical, Inc.
Direct Image Flat
Description:... The Flat is designed for routine vitrectomy, optic nerve neurotomy and induction of posterior
vitreous detachments. It is also useful for macular hole surgery, epiretinal membranes and for removal of tractional epiretinal ....
Company:Volk Optical, Inc.
Mini Quad® (ACS)
Description:... surgery, repairing giant retinal tears, diagnosing and treating anterior proliferative vitreoretinopathy and for examining the peripheral retina in a
vitreous cavity filled with air. (ACS) AutoClave Sterilizable Lenses The ACS Vitrectomy Lenses from Volk can be safely steam-sterilized and can withstand ...
Company:Volk Optical, Inc.
clariVit Wide Angle
Description:... retina, detailed retinal detachment surgery, treating retinal tears, diagnosis and treatment of anteriorproliferative vitreoretinopathy, when the
vitreous cavity is filledwith ....
Company:Volk Optical, Inc.
Mini Quad®
Description:... surgery, repairing giant retinal tears, diagnosing and treating anterior proliferative vitreoretinopathy and for examining the peripheral retina in a
vitreous cavity filled with ....
Company:Volk Optical, Inc.
EchoScan US-1800
Description:... conversion at 1550m/s. The new Phakic 2 mode measures
axial length by calculating each tissues sonic velocity for conversion: anterior chamber and
vitreous depth at 1532m/s, and crystalline lens
thickness at 1641m/s. Phakic 2 mode provides precise axial length measurement accuracy, even in patients ...
Company:NIDEK, Inc.
ISYSTEM-ABD A/B-scan unit
Description:... featuring an analog oscilloscope (static deflection) display. This provides substantially more speed and resolution than low cost video monitors.
vitreous structures such as posterior hyaloid, syneresis, inflammatory cells, as well as tumor vascularity and macular edema are routinely detected. On-screen ...
Company:Innovative Imaging Inc.
CineScan A/B
Description:... and diagnostic capability previously unavailable. See pathology formerly unavailable, especially in the vitreous. Adjust the gain up to 105db to view
vitreous details that would be invisible at a standard 90db setting - or reduce it to clearly distinguish the different layers of the ocular wall. The ...
Company:Quantel Medical, Inc.
CineScan A/B-S
Description:... and diagnostic capability previously unavailable. See pathology formerly unavailable, especially in the vitreous. Adjust the gain up to 105db to view
vitreous details that would be invisible at a standard 90db setting - or reduce it to clearly distinguish the different layers of the ocular wall. The ...
Company:Quantel Medical, Inc.
Healon GV
Description:... substance that is widely distributed in the extracellular matrix of connective tissues in both animals and man. For example, it is present in the
vitreous and aqueous humor of the eye, the synovial fluid, the skin, and the umbilical cord. Sodium hyaluronates derived from various human or animal tissues ...
Company:Advanced Medical Optics, Inc.
Healon 5 (viscoadaptive)
Description:... substance that is widely distributed in the extracellular matrix of connective tissues in both animals and man. For example, it is present in the
vitreous and aqueous humor of the eye, the synovial fluid, the skin, and the umbilical cord. Sodium hyaluronates derived from various human or animal ...
Company:Advanced Medical Optics, Inc.
Three-mirror Contact Lens 907
Description:... The best combination with the Haag-Streit 900 Slitlamps. For examination of the entire fundus, the
vitreous and the iridocorneal angle. For children up to 4 years of age. 11 mm internal diameter of the cornea ....
Company:Haag-Streit USA, Inc.
Three-mirror Contact Lens 906 S
Description:... The best combination with the Haag-Streit 900 Slitlamps. For examination of the entire fundus, the
vitreous and the iridocorneal angle. For newly born children. 10 mm internal diameter of the cornea ....
Company:Haag-Streit USA, Inc.
Three-mirror Contact Lens 906
Description:... The best combination with the Haag-Streit 900 Slitlamps. For examination of the entire fundus, the
vitreous and the iridocorneal angle. For newly born children. 10 mm internal diameter of the cornea ....
Company:Haag-Streit USA, Inc.
One-mirror Contact Lens 904
Description:... This contact glass serves to examine the ora serrata, the pars plana and the extreme peripheral parts of the
vitreous body and the ocular ....
Company:Haag-Streit USA, Inc.
Three-mirror Contact Lens 903 S
Description:... The best combination with the Haag-Streit 900 Slitlamps. For examination of the entire fundus, the
vitreous and the iridocorneal angle. The classic Goldmann ....
Company:Haag-Streit USA, Inc.
Three-mirror Contact Lens 903
Description:... The best combination with the Haag-Streit 900 Slitlamps. For examination of the entire fundus, the
vitreous and the iridocorneal angle. The classic Goldmann ....
Company:Haag-Streit USA, Inc.
Contact Glass 901
Description:... For the binocular slit observation of the pupil, the macula, its surroundings out to 30 as well as the central
vitreous body sections. Easy to use, lightweight glass provides a direct ....
Company:Haag-Streit USA, Inc.
SL 120 Biomicroscopic Slit Lamp
Description:... The field of application of the SL 120 Slit Lamp extends from the anterior ocular segment and the
vitreous right back to the fundus. It is the ideal configuration for observation, measurement, diagnosis and ....
Company:Carl Zeiss Meditec, Inc.
Maumenee Vitreous Aspirating Cannula
Description:... Maumenee
vitreous aspirating cannula, 18 ....
Company:American Ophthalmic Laboratories, LLC.
Healon Vitreous Aspirating Cannula
Description:... Healon
vitreous aspirating cannula, 21 ....
Company:American Ophthalmic Laboratories, LLC.
Harmony Total TTC®
Features:...
One cutter for both core vitrectomy and
vitreous shaving at
vitreous base, detached retina, etc.
Linear ... cutting range.
Optimum combination of efficient
vitreous removal and minimized retinal traction. ...
Company:Dutch Ophthalmic, USA
Crystalens™ Accommodating Posterior Chamber Intraocular Lens
Features:... Designed to take advantage of
vitreous cavity pressure changes by locating against the
vitreous face.
This allows the lens optic to move forward ... as well as to pressure changes between the
vitreous cavity and the anterior chamber.
The hinged ...
Company:eyeonics, Inc.
EYESI Ophthalmosurgical Simulator
Features:... (tweezers*): Using tweezers to manipulate solid objects in the
vitreous body and to remove objects from the
vitreous body.
Vitrectomy (vitrectomy unit*): Learning how to use the ...
Company:VRmagic GmbH
Fison Indirect Ophthalmoscope
Features:... 22 watt tungsten light, allows viewing of the retina through cataracts,
vitreous and ....
Company:Keeler Instruments Inc.
Microdiathermy System - 1100
Features:... System offers the best combination of performance and versatility resulting in the preferred system for use during retinal detachment surgery or
vitreous surgery. ...
Company:Dutch Ophthalmic, USA
Khosla Irrigation/Aspiration Vitrectomy Unit
Features:... Electronically controlled
light weight
powerful
vitreous cutter working with N2O or CO2 to provide necessary cutting action. ...
Company:Khosla Medical & Surgical, Inc.
Acri.Flu-an
Features:... defolding and stabilization of the detached retina during vitreoretinal surgery in case of remove subluxated lenses and foreign bodies from the
vitreous after previous vitrectomy. Complete free for containing by-product. High specific weight. 5 ml or 7 ml vial, sterilized in the finished container, ...
Company:Acri.Tec GmbH
Acri.Deca
Features:... defolding and stabilization of the detached retina during vitreoretinal surgery in case of remove subluxated lenses and foreign bodies from the
vitreous after previous vitrectomy. Complete free for containing by-product. High specific weight. 5 ml or 7 ml vial, sterilized in the finished container, ...
Company:Acri.Tec GmbH
Acri.Octa
Features:... defolding and stabilization of the detached retina during vitreoretinal surgery in case of remove subluxated lenses and foreign bodies from the
vitreous after previous vitrectomy. Complete free for containing by-product. High specific weight. 5 ml or 7 ml vial, sterilized in the finished container, ...
Company:Acri.Tec GmbH
Ispan SF6 Intraocular Gases
Features:... ISPAN Sulfur Hexafluoride (SF6), is a liquefied gas under pressure and, is administered by injection into the
vitreous cavity. It is packaged in aluminum lecture bottles, which ensure no change in gas contents due to oxidation or particulate contamination. Regulator ...
Company:Alcon Laboratories
Ispan C3F8 Intraocular Gases
Features:... ISPAN Perfluoropropane (C3F8), is a liquefied gas under pressure and is administered by injection into the
vitreous cavity. I t is packaged in aluminum lecture bottles, which ensure no change in gas contents due to oxidation or particulate contamination. Regulator ...
Company:Alcon Laboratories
Cytology, Vitreous Fluid
Description: ARUP Laboratories is a national reference laboratory and a worldwide leader in innovative laboratory research and development. ARUP offers an extensive test menu of highly complex and unique medical tests in clinical and anatomic pathology. Owned by the University of Utah, ARUP Laboratories' ...
Company:ARUP Laboratories
Wilson Vitreous Foreign Body Forceps
Description: Three 2 mm prongs with 0.1 mm angled tips. 20 gauge (.89 mm) diameter shaft. Lightweight Wilson style squeeze handle with dull finish. Most popular size or ....
Company:Bausch & Lomb Storz
Maumenee-Barraquer Vitreous Sweep Spatula - Left
Description: 10 mm angled tip with indentation on side and gently curved blade. Round knurled handle with polished finish. Indentation: left ....
Company:Bausch & Lomb Storz
Maumenee-Barraquer Vitreous Sweep Spatula - Right
Description: 10 mm angled tip with indentation on side and gently curved blade. Round knurled handle with polished finish. Indentation: right ....
Company:Bausch & Lomb Storz