Akahoshi Prechop (temporal approach)
...haco tip minimizes wound damage and contributes to self sealing wound. Ultrasound time can be reduced to half of conventional grooving method.......ght glasses that display the magnified image. This self contained, battery-operated system offers optimal portability, ease of use and comfort. FlipperPort can easily connect with a TV or monitor. No assembly is required. One year limited warranty....Microplate Washers - ELx50 96-/384-Well Auto Strip Washer
... patented Dual-Action 16-channel manifold. It is a self contained and programmable instrument. It allows for full control of precise fluidic delivery from the gentle dripping of a simple squeeze bottle to the full force of pressure delivery systems. ELx50/12V processes 1 x 12 strips or a full 96-well plat......tegrated and cooled imaging system is a completely self contained unit built with a long list of standard features including all-electronic-variable transilluminator and EPI lighting.......2-bit integrated and cooled system is a completely self contained unit built with a long list of standard features including all-electronic-variable transilluminator and EPI lighting.......6-bit integrated and cooled system is a completely self contained unit built with a long list of standard features including all-electronic-variable transilluminator and EPI lighting....Valin Hemilaminectomy Retractor
Valin Hemilaminectomy Retractor, self retaining with rack and pinion action.......avity when using Ritleng Bicanalicular systems and self threading Monoka systems....CARDIA Atrial Septal Defect Closure Device
...aneous closure of ASD's with a super low profile.A self centering mechanism is incorporated into the twelve arm device for optimal positioning and stability in the ASD.An integral locking delivery and retrieval mechanism ensures safe and stable positioning of the CARDIA ASD device within the atrial septum...Evolis™ is a self contained microplate processor designed to completely automate microtiter plate based EIA assays. The system is dedicated to smooth and safe handling of materials encountered in todays busy laboratory. The system architecture allows laboratories easy......in motorized calibration weight enabling automatic self calibration.......in motorized calibration weight enabling automatic self calibration.......in motorized calibration weight enabling automatic self calibration....Freezing Stage for Microtome, 38 mm x 38 mm
... is supplied for this purpose. All water tubes are self sealing. All stages require running water for operating. If a tap is not conveniently available in the lab, a circulating pump and tank can be used.Have you checked out Vibratomes Sliding Microtomes ?...Freezing Stage for Microtome, 76.2 mm x 79.4 mm
... is supplied for this purpose. All water tubes are self sealing. All stages require running water for operating. If a tap is not conveniently available in the lab, a circulating pump and tank can be used. 110 Volt VersionHave you checked out Vibratomes Sliding Microtomes ?...Freezing Stage for Microtome, 38 mm x 38 mm, 220V
... is supplied for this purpose. All water tubes are self sealing. All stages require running water for operating. If a tap is not conveniently available in the lab, a circulating pump and tank can be used.Have you checked out Vibratomes Sliding Microtomes ?...Freezing Stage for Microtome, 76.2mmx79.4mm, 220V
... is supplied for this purpose. All water tubes are self sealing. All stages require running water for operating. If a tap is not conveniently available in the lab, a circulating pump and tank can be used.Have you checked out Vibratomes Sliding Microtomes ?...IRMA TRUPOINT Blood Analysis System
...nt's side - the true point of care. This powerful, self contained system can easily be transported from OR to CCU to ICU, or wherever you need it for immediate results and more timely interventions....Medonic 620 Hematology Analyzer Series
...tors that reduce the need for manual intervention, self cleaning apertures that help to maintain sample integrity and virtually no daily or weekly maintenance that will reduce time and cost. Each analyzer is equipped with an expanded quality control module that allows the laboratory to maintain accurate d...... and strips with the ELx50 Auto Strip Washer. As a self contained and programmable instrument, the ELx50 allows for full control of precise fluidic delivery from the gentle dripping of a simple squeeze bottle to the full force of pressure delivery systems.......mable Power Supply is completely programmable with self prompting menus and multiple operation modes....Core Malaria Pv/Pf is a self performing, qualitative, sandwich immunoassay for the detection and differentiation of vivax malaria and falciparum malaria in whole blood samples....Core Malaria Pf is a rapid self performing, qualitative, two site sandwich immunoassay for the determination of P. falciparum specific histidine rich protein 2 (Pf HRP-2) in whole blood samples......sting and ETDRS acuity testing are provided in the self standardized CSV-1000 instrument. Patented photocell circuitry automatically monitors and calibrates instrument testing light levels....For the measurement of vaginal pH as part of a self examination programme to help reduce the risk of pre-term birth...