Beehive Millennium - Long-term Epilepsy Monitoring
Description:... product line, combines decades of experience in epilepsy monitoring with the technology of the 21st ... and review capabilities that are specialized for epilepsy monitoring applications. Beehive Millennium ... and options designed specifically for the epilepsy monitoring unit, including Nurse Alarm systems, ...Integra Epilepsy Sphenoidal Electrodes
Description:... provide a less invasive method of recording brain activity in the epilepsy patient. Like all Integra epilepsy electrodes, sphenoidal electrodes are fabricated from implant-grade ...Integra Epilepsy Strip Electrodes
Description:... Integra epilepsy cortical strip electrodes are extra thin and flexible to facilitate ... and secure attachment to the patented connection system. Like all Integra epilepsy electrode designs, they are available with implant grade stainless steel ...Integra Epilepsy Flex Connector Grid Electrodes
Description:... The patented Integra epilepsy Flex Connector represents a significant advance in the design of epilepsy electrodes. This versatile 64-contact connector simplifies lead tunneling ...Integra Epilepsy Gates/Dunn Electrodes
Description:... Designed in collaboration with Drs. John R. Gates and Mary E. Dunn at the Minnesota epilepsy Group, Gates/Dunn electrodes are designed for reliability, safety and ease of use. For cortical strip and grid electrodes, platinum contacts are ...Integra Epilepsy Grid Electrodes
Description:... Integra epilepsy grid electrodes are thin and flexible for easier placement and to conform to the curvature of the cortical surface. Lead tunneling is done using a ...Integra Epilepsy Foramen Ovale Electrodes and Accessories
Description: Foramen ovale electrodes typically are guided through the foramen ovale and are positioned on the medial surface of the temporal lobe. The ultra-thin 1.0 mm diameter electrodes are flexible yet firm enough to allow guidance to the desired target ....Integra Epilepsy Specialty Electrodes
Description: Dual-sided, Interhemispheric Grid Electrode with 16 Contact Leads; Cortical Grid Electrode with 16 Contact Leads; Pediatric Grid Electrode with Flex Connector, 0.5 cm ...Integra Epilepsy Epidural Peg Electrodes and Accessories
Description: Peg electrodes typically are positioned in a burr hole to enable epidural recording of brain activity. They have platinum contacts and are furnished in several lengths to accommodate various skull thicknesses. A 4.6 mm twist drill is suitable for installation of peg electrodes in the ....Integra Epilepsy Depth Electrodes
Description: These are superior quality electrodes, fabricated from a single length of polyurethane tubing for strength and uniform smoothness. They are furnished with a specially-designed rigid stylet to facilitate stereotactic placement in the ....