Lindstrom Lasik Spatula and Marker
This instrument marks the cornea for centration of the flap and provides a spatula for flap management in primary and enhancement cases. The corneal marker has a pararadial mark that is used to ensure proper alignment of the flap after treatment. The spatula may be used to atraumati...... to provide open approaches of the keratome to the cornea for either the left or right eye. Lightweight wire design adds to the comfort of the instrument when in place....Anterior Chamber Irrigating Cannula
...and viscoeastic substances, as well as keeping the cornea moist during surgery. 4 mm from bend to tip.......in jaws to allow insertion through tunnel or clear cornea incision. Locking. Made in titanium.......es pictures in three dimensions. The center of the cornea is measured very precisely because of this rotational imaging process. The measurement process lasts less than two seconds and minute eye movements are captured and corrected simultaneously. By measuring 25,000 true elevation points, precise represen......act lenses can be used as a bandage to protect the cornea and to relieve corneal pain in the treaent of acute or chronic ocular pathologies such as bullous keratopathy, corneal erosions, entropion, corneal edema, and corneal dystrophies as well as post-surgical conditions resulting from cataract extraction ......y designed for increased working distance from the cornea (7mm), making it more practical than competitive pan fundus lenses. Its small 30.2mm diameter housing also proves highly useful for dynamic fundoscopy, allowing the lens to be more easily manipulated in the orbital area of the eye, increasing its dyn......lization, false readings throughindentation of the cornea or the need for any drops.Another measurement which can be made, and is very usefulin post-ablation management care of the patient, is the ability tomeasure separately the epithelium.Additionally to this, there is also a programme into which can been......r surgery or trauma. 8mm diameter, lint free keeps cornea moist. Protects retina from operating microscope light rays.......ewly born children. 10 mm internal diameter of the cornea part....Three-mirror Contact Lens 906 S
...ewly born children. 10 mm internal diameter of the cornea part....... to 4 years of age. 11 mm internal diameter of the cornea part....Laser 3 mirror Contact Lens 906 L
...newly born children 10 mm internal diameter of the cornea part. Designed to work with argon/YAG Lasers....Laser 3 mirror Contact Lens 907 L
...p to 4 years of age 11 mm internal diameter of the cornea part. Designed to work with argon/YAG Lasers.......ages and precision measurement capabilities of the cornea and anterior segments of the human eye. Artemis is a very high frequency (VHF) ultrasound eye scanner. In use, the patient leans forward placing their head onto an adjustable headrest. The headrest's unique design permits the patient to pull away qui...The PASCAL Dynamic Contour Tonometer
... of ocular pulse amplitude (OPA) upon touching the cornea for a few seconds. It measures pulsatile IOP directly and continuously (dynamically)....IntraLase FS Femtosecond Laser
...ses a significant level of vacuum to applanate the cornea through a suction ring and hold it tightly as the ... laser energy directly to the stromal layer of the cornea through a disposable glass lens. The outer surface of the cornea suffers no trauma, and the procedu...The Pach IV is the premier product for cornea thickness measurement in conjunction with Glaucoma screening.......ed on the theory of wavefront measurements. If the cornea and lens of a patient's eye were perfect, a matching set of plane waves entering the eye world focus onto a very small spot on the retina. However, in actual human eyes the waves are distorted causing a slight blur on the retina. Although this is sub......d pressure points resulting in an improved lens to cornea fitting relationship. Better fit and alignment means improved comfort and physiology.......alyses an accurate ring pattern projected onto the cornea via precision optics......e taken the picture you can ascertain where on the cornea you have photographed. This is displayed on a low ... of a small box will pinpoint exactly where on the cornea it has photographed the cells. This is very valuable when you wish to return to the same location on......directions. It allows you to select an area on the cornea to measure the thickness. It also has built-in sof...d, the unit will also identify the location on the cornea in which the measurement was obtained. The information on the thickness of the cornea can also be st...Paragon CRT 100 (paflufocon D)
..., causing it to temporarily flatten. The flattened cornea redirects light onto the back surface of the eye (...that can compensate for nearsightedness. Since the cornea is elastic, it gradually regains its shape throughout the day (causing nearsightedness to return). U......, causing it to temporarily flatten. The flattened cornea redirects light onto the back surface of the eye (...that can compensate for nearsightedness. Since the cornea is elastic, it gradually regains its shape throughout the day (causing nearsightedness to return). U...Paragon Quadra RG (paflufocon B)
..., causing it to temporarily flatten. The flattened cornea redirects light onto the back surface of the eye (...that can compensate for nearsightedness. Since the cornea is elastic, it gradually regains its shape throughout the day (causing nearsightedness to return). U...Paragon Quadra RG 100 (paflufocon D)
..., causing it to temporarily flatten. The flattened cornea redirects light onto the back surface of the eye (...that can compensate for nearsightedness. Since the cornea is elastic, it gradually regains its shape throughout the day (causing nearsightedness to return). U...Orthokeratology (oprifocon A) Contact Lenses
..., causing it to temporarily flatten. The flattened cornea redirects light onto the back surface of the eye (...that can compensate for nearsightedness. Since the cornea is elastic, it gradually regains its shape throughout the day causing nearsightedness to return. Usu...Cellchek CC-7000 with Pachymeter
...00 will automatically measure the thickness of the cornea at the same time it photographs the corneal endothelium. Therefore in three seconds you have a picture of the cells and the readout of the corneal thickness on the screen. The other exception over the CC-5000 is the CC-7000 will allow you to perform ...ViewPoint CK System (Conductive Keratoplasty)
...iofrequency (RF) energy to temporarily reshape the cornea and therefore adjust its refractive characteristic...es a purse-string effect that steepens the central cornea through a ring of application spots around the periphery of the cornea. Several studies have conclud......hermally contracts the tissue, causing the central cornea to steepen. A bandage soft contact lens is usually placed on the eye until the following day. They eye may have some irritation for the first few days....... study published in mid-2002, the patients central cornea thickness (CCT) is an important and necessary biometric parameter in risk assessment for this patient population.......id the disturbing shadows of nose & eyebrow on the cornea we use a small cone. Its particular purpose is to ...id the disturbing shadows of nose & eyebrow on the cornea we use a small cone. Its particular purpose is to provide a large measurement area. Intelligent ...LSM-12000 High-Magnification Slit-Lamp Biomicroscope
...It can examine ocular tissue from the front of the cornea to the back of the lens. Corneal stromal changes, cataractous changes, and posterior capsule changes can be seen and documented as can corneal endothelial changes. With the LSM-12000 you see a live, true real-time image. Unlike some instruments, you ......delaminate or separate the epithelial layer of the cornea above Bowman's layer. The Centurion SES eliminates the need for alcohol currently used during LASEK to delaminate the epithelium. By eliminating the need for alcohol and providing a 'minimal-touch' surgical approach, the SES is designed to reduce tra......t does not require the surgeon to cut the patients cornea or apply alcohol as is done in comparable procedur...e tissue. The tissue is then lifted away from the cornea so that a laser can be applied to reshape it. This entire process, Epi-LASIK, produces virtually ins...... surgeons, as calculating IOL power for a modified cornea is difficult. True corneal power following RK, ALK, PRK and LASIK is difficult to accurately measure by keratometry or topography. For example, keratometry and simulated keratometry by topography will typically overestimate central corneal power in p...Geggel Corneal Transplant Marker
.... Each marker places inner and outer points on the cornea to achieve a precise and rapid 16 or 24 bite anti-torque closure. The special center pointer provides precise centralized alignment for symmetrical suture placement. The markers are useful for running suture placements for trephine openings of 7.75mm......is a biocompatible, flexible, one-piece artificial cornea (keratoprosthesis) designed to replace a scarred or diseased native cornea. The World Health Organisation (WHO) reports that corneal blindness affects more than 10 million people worldwide, however only 100,000 people receive corneal transplants each......raft. The graft is then sutured into the patient's cornea like a standard graft. The Boston Keratoprosthesis has been under development since the 1960s and has gradually been perfected. It received FDA clearance in 1992. About 600 implantations have been performed. It is the most commonly used keratoprosthe...Keratoprosthesis for artificial cornea surgery is a procedure for restoring the sight of patients suffering from severely damaged anterior segment due to trauma, chemical burns, infections, etc. OCULAID Keratoprosthesis, REF 299, will be supplied on special request only.The KP is delivere...The Pach IV is the premier product for cornea thickness measurement in conjunction with Glaucoma screening.......ased on the principle of convex applanation of the cornea during the cut. This results in the cornea being applanated evenly from the beginning of the cut to the end. This ensures that the intraocular ......ogen Technology bulb produce less reflexes off the cornea and clear, high resolution images of the fundus that are up to 100% brighter.......y designed for increased working distance from the cornea (7mm), making it more practical than competitive pan fundus lenses. Its small 30.2mm diameter housing also proves highly useful for dynamic fundoscopy, allowing the lens to be more easily manipulated in the orbital area of the eye, increasing its dyn...... dynamic movement and viewing on the average sized cornea increasing the lens dynamic field of view and mobility for detailed inspection of the retina extending to the far periphery....