Testosterone RIA Test
Description:... with only a small amount derived from peripheral
conversion of androstenedione [2]. In adult women, it has ... of serum testosterone is derived from peripheral
conversion of androstenedione secreted by the adrenal and ...
In males, testosterone, either directly or after
conversion to DHT, normally functions in fetal Wolffian duct ...
Company:Diagnostic Systems Laboratories, Inc.
Testosterone EIA Test
Description:... with only a small amount derived from peripheral
conversion of androstenedione [2]. In adult women, it has ... of serum testosterone is derived from peripheral
conversion of androstenedione secreted by the adrenal and ... males, testosterone, either directly or after
conversion to DHT, normally functions in fetal Wolffian duct ...
Company:Diagnostic Systems Laboratories, Inc.
Androstenedione EIA Test
Description:... exceed those of testosterone in women in whom significant extra-adrenal
conversion of androstenedione to testosterone occurs [1,2,3].
Measurement of serum ... rates measured in peripheral blood and studies on the possible site of its
conversion to testosterone. J Clin Invest 45:301-313, 1966.
Pang S, Riddick L: ...
Company:Diagnostic Systems Laboratories, Inc.
Androstenedione RIA Test
Description:... exceed those of testosterone in women in whom significant extra-adrenal
conversion of androstenedione to testosterone occurs [1,2,3].
Measurement of serum ... rates measured in peripheral blood and studies on the possible site of its
conversion to testosterone. J Clin Invest 45:301-313, 1966.
Pang S, Riddick L: ...
Company:Diagnostic Systems Laboratories, Inc.
Estrone RIA Test
Description:... women, the major portion of estrone is derived from peripheral tissue
conversion of androstenedione. Interconversion of estrone and estradiol also occurs ... not decline as dramatically as estradiol levels, possibly due to increased
conversion of androstenedione to estrone [3].
Baird DT, et al. Rec Progr Horm ...
Company:Diagnostic Systems Laboratories, Inc.
Thumper 1007
Description:... Thumper Board allows better manual CPR to be started immediately, and easy
conversion to Thumper CPR
Set-up to patient application can be done in less than ... Thumper into the board without interrupting manual CPR. With two people,
conversion from manual to Thumper CPR is made with no loss of support.
Transfer ...
Company:Michigan Instruments, Inc.
MRAnywhere
Description:... Medical Records (EMR) software that lets you access your charts from within your office, hospital, home using the World Wide Web. MRAnywhere offers
conversion from hard-copy records to electronic medical records by outsourcing the ....
Company:Worldtech USA, Inc.
DHEA RIA Test
Description:... DHEA is an important androgen as circulating DHEA levels may be several-fold higher than testosterone concentrations, and rapid peripheral tissue
conversion to more potent androgens (androstenedione and testosterone) and estrogens may occur. In addition, DHEA has a relatively low affinity for sex-hormone ...
Company:Diagnostic Systems Laboratories, Inc.
DHEA EIA Test
Description:... DHEA is an important androgen as circulating DHEA levels may be several-fold higher than testosterone concentrations, and rapid peripheral tissue
conversion to more potent androgens (androstenedione and testosterone) and estrogens may occur. In addition, DHEA has a relatively low affinity for sex-hormone ...
Company:Diagnostic Systems Laboratories, Inc.
Mars
Description:... operating theatre is ready for all current and future developments in the specialist surgical fields. Its modern design allows a quick, problem-free
conversion to meet the most diverse tasks. The individual components are connected securely and sturdily to MARS through a special, absolutely precise coupling ...
Company:TRUMPF Medical Systems, Inc.
DHEA-S-7 RIA Test
Description:... Dehydroepiandrosterone sulfate (DHEA-S) is the sulfate ester of DHEA, derived from sulfated precursors and by enzymatic
conversion of DHEA in adrenal and extradrenal tissues. DHEA is the major C19 steroid secreted by the adrenal cortex, and is a precursor for testosterone and ...
Company:Diagnostic Systems Laboratories, Inc.
DHEA-S-7 EIA Test
Description:... Dehydroepiandrosterone sulfate (DHEA-S) is the sulfate ester of DHEA, derived from sulfated precursors and by enzymatic
conversion of DHEA in adrenal and extradrenal tissues. DHEA is the major C19 steroid secreted by the adrenal cortex, and is a precursor for testosterone and ...
Company:Diagnostic Systems Laboratories, Inc.
DHEA-S-7 (saliva) EIA Test
Description:... Dehydroepiandrosterone sulfate (DHEA-S) is the sulfate ester of DHEA, derived from sulfated precursors and by enzymatic
conversion of DHEA in adrenal and extradrenal tissues. DHEA is the major C19 steroid secreted by the adrenal cortex, and is a precursor for testosterone and ...
Company:Diagnostic Systems Laboratories, Inc.
DHEA-S RIA Test
Description:... Dehydroepiandrosterone sulfate (DHEA-S) is the sulfate ester of DHEA, derived from sulfated precursors and by enzymatic
conversion of DHEA in adrenal and extradrenal tissues. DHEA is the major C19 steroid secreted by the adrenal cortex, and is a precursor for testosterone and ...
Company:Diagnostic Systems Laboratories, Inc.
ELB600H Portable Scale
Description:... Portable - Battery Powered (6 size AA required). Fast, Lightweight Strain Gage Mechanism. Unit
conversion (g, ct, oz, ozt, GN, dwt, mom, dwt, tael), Specific Gravity calculation, Piece Counting and Percent Measure functions, Auto Print. Optional hook ...
Company:Shimadzu Medical Systems
ELB3000 Portable Scale
Description:... Portable - Battery Powered (6 size AA required). Fast, Lightweight Strain Gage Mechanism. Unit
conversion (g, ct, oz, ozt, GN, dwt, mom, dwt, tael), Specific Gravity calculation, Piece Counting and Percent Measure functions, Auto Print. Optional hook ...
Company:Shimadzu Medical Systems
ELB300 Portable Scale
Description:... Portable - Battery Powered (6 size AA required). Fast, Lightweight Strain Gage Mechanism. Unit
conversion (g, ct, oz, ozt, GN, dwt, mom, dwt, tael), Specific Gravity calculation, Piece Counting and Percent Measure functions, Auto Print. Optional hook ...
Company:Shimadzu Medical Systems
ELB12K Portable Scale
Description:... Portable - Battery Powered (6 size AA required). Fast, Lightweight Strain Gage Mechanism. Unit
conversion (g, ct, oz, ozt, GN, dwt, mom, dwt, tael), Specific Gravity calculation, Piece Counting and Percent Measure functions, Auto Print. Optional hook ...
Company:Shimadzu Medical Systems
SpectraMax M2 multi-detection microplate reader w/ dual-mode cuvette port
Description:... and heterogeneous microplate assays to be performed in this flexible system. The FI and Abs microplate reader with built-in cuvette port allows easy
conversion and optimization of very-low-throughput assays into medium-high-throughput microplate assays. The SpectraMax M2 allows faster, more precise results ...
Company:Molecular Devices Corporation
XCD-X710CR Color Raw Digital Camera
Description:... called a "Bayer filter") and outputs the "raw color" pixel values in 8 or 10 bit to be converted to a color image on the computer. The color
conversion that takes place in the computer is supported by Sonys new IEEE 1394 software and most 3rd party Firewire® (IIDC) compatible software. • XGA ...
Company:Sony Electronics
XCD-SX910CR Color Raw Digital Camera
Description:... called a "Bayer filter") and outputs the "raw color" pixel values in 8 or 10 bit to be converted to a color image on the computer. The color
conversion that takes place in the computer is supported by Sonys new IEEE 1394 software and most 3rd party Firewire (IIDC) compatible software. SXGA ...
Company:Sony Electronics
Estradiol, Ultra-Sensitive RIA Test
Description:... Estrone and estradiol are interconverted in many body tissues. In men, small amounts of estradiol are produced in the testes and from peripheral
conversion of androgens. The biological actions of estradiol include stimulation of linear bone growth, acceleration of epiphyseal closure, stimulation of ...
Company:Diagnostic Systems Laboratories, Inc.
Estradiol RIA Test
Description:... Estrone and estradiol are interconverted in many body tissues. In men, small amounts of estradiol are produced in the testes and from peripheral
conversion of androgens. The biological actions of estradiol include stimulation of linear bone growth, acceleration of epiphyseal closure, stimulation of ...
Company:Diagnostic Systems Laboratories, Inc.
Estradiol EIA Test
Description:... Estrone and estradiol are interconverted in many body tissues. In men, small amounts of estradiol are produced in the testes and from peripheral
conversion of androgens. The biological actions of estradiol include stimulation of linear bone growth, acceleration of epiphyseal closure, stimulation of ...
Company:Diagnostic Systems Laboratories, Inc.
3rd Generation Estradiol RIA Test
Description:... Estrone and estradiol are interconverted in many body tissues. In men, small amounts of estradiol are produced in the testes and from peripheral
conversion of androgens. The biological actions of estradiol include stimulation of linear bone growth, acceleration of epiphyseal closure, stimulation of ...
Company:Diagnostic Systems Laboratories, Inc.
REVOLUTION shaver system
Description:... shaver unit for the duration of its use. The REVOLUTION pump can be adapted to control suction through other manufacturer's shavers using a dedicated
conversion box.
Versatility and Economy
The REVOLUTION system provides an unsurpassed level of control over arthroscopic operative sites through its ...
Company:Atlantech Medical Devices Ltd.
Epik® Uni-System
Description:... reduce hospital stay, shorten recovery time, restore normal kinematics, and maximize ROM. In addition, bone stock is preserved to facilitate future
conversion to a tricompartment replacement as long as conservative operative techniques have been ....
Company:Encore Medical Corporation
EchoScan US-1800
Description:... Nidek's US-1800 also incorporates a new axial length measuring mode. Normal phakic mode measures axial length by calculating sonic velocity for
conversion at 1550m/s. The new Phakic 2 mode measures
axial length by calculating each tissues sonic velocity for conversion: anterior chamber and vitreous ...
Company:NIDEK, Inc.
Testosterone EIA Reproductive Markers 020-DR-1559
Description:... testosterone is secreted
primarily by the Leydig cells of the testes; in females ca. 50% of circulating testosterone is derived from
peripheral
conversion of androstenedione, ca. 25% from the ovary and ca. 25% from the adrenal glands. The Testosterone ELISA KIT is based on the competition principle and ...
Company:ALPCO Diagnostics
ACE - REA Hypertension / Cardiac Evaluation, Cardiovascular 001-RK-ACD Angiotensin Converting Enzyme
Description:... peptide and can be cleaved to be released into the blood circulation as soluble enzyme.
Angiotensin converting enzyme (ACE) catalyzes the
conversion of angiotensin I to angiotensin II. The enzyme also mediates the cleavage of a synthetic substrate, 3H hippuryl-glycylglycine, into 3H-hippuric acid ...
Company:ALPCO Diagnostics
Cervical Spinal Compression Plate Acc. To Matzen
Description:... the vertebral bodies, if possible along the center line. It has instrument repositor: distraction, which is necessary to remove the vertebral disc,
conversion in compression after filling with bone transplant. Compression plate: cranially and caudally slotted for use of the repositor, mono- and bisegmental ...
Company:Ulrich GmbH & Co. KG
BioTears Oral GelCaps
Features:... GelCaps contain the optimal blend of Omega 3 and Omega 6 essentials fatty acids, plus all the nutrient co-factors suggested to enhance the metabolic
conversion associated with the tear-specific series one anti-inflammatory prostaglandin, PGE1.
BioTears Oral GelCaps include nutrients that are suggested to ...
Company:Biosyntrx, Inc.
Portable Drug Companion Pharmacology Suite
Features:... being low and 5 being high Internationally Comprehensive with SI Lab Units presented along with American units, an SI calculator, complete metric
conversion calculators, and even includes 1200 Canadian drug trade names in drug monographs and incorporated into the Drug Interactions Generator Comprehensive ...
Company:PEPID, LLC
Micro Slide Files
Features:... compartment serves as a protective barrier against damage to the stored slides For other storage needs, all or alternate partitions are removed for
conversion to larger size compartments For cataloging and slide retrieval, each compartment is numerically indexed to a permanent chart on the underside of the ...
Company:Electron Microscopy Sciences
S/5 Collect4
Features:... (Datex Record Interface format) for further analysis in offline mode. Saving in ASCII format available in both modes
In offline mode, it allows
conversion of physiological data files from Datex-Ohmeda S/5 Central into .drc format
You can make notes and add markers during data collection, for easy ...
Company:Datex-Ohmeda, Inc.
S/5 Collect
Features:... (Datex Record Interface format) for further analysis in offline mode. Saving in ASCII format available in both modes
In offline mode, it allows
conversion of physiological data files from Datex-Ohmeda S/5 Central into .drc format
You can make notes and add markers during data collection, for easy ...
Company:Datex-Ohmeda, Inc.
Disposable Blades Rusch Lite® Macintosh
Features:... free
New Macintosh Slim design for enhanced view
New Macintosh Slim Lite 1 size
Works with your current standard/conventional system
Allows
conversion to a disposable system economically
Reduces risk of cross contamination
Rsch Lite™ Kit comes with a full set of disposable blades and one ...
Company:Rusch, Inc.
Disposable Blades Rusch Lite® Set
Features:... free
New Macintosh Slim design for enhanced view
New Macintosh Slim Lite 1 size
Works with your current standard/conventional system
Allows
conversion to a disposable system economically
Reduces risk of cross contamination
Rsch Lite™ Kit comes with a full set of disposable blades and one ...
Company:Rusch, Inc.
Disposable Blades Rusch Lite® Miller
Features:... free
New Macintosh Slim design for enhanced view
New Macintosh Slim Lite 1 size
Works with your current standard/conventional system
Allows
conversion to a disposable system economically
Reduces risk of cross contamination
Rsch Lite™ Kit comes with a full set of disposable blades and one ...
Company:Rusch, Inc.
SureCut M3500 Fine Thread Conversion Kit
Description:
Conversion kit that has 1 - 15 micron feed screw with 1 micron increments for fine cutting (factory ...
Company:myNeuroLab.com