Ocular Three Mirror 10 mm Gonio
...hylcellulose. The fundus can be viewed through the central axis of the lens. Multi-layer polymer coating protects mirrors and is compatible with most disinfecting methods. No methylcellulose required....Roche OMNI C Blood Gas Analyzer
... oxygen. Use it as a cost effective backup for the central lab or for remote placements in critical care areas....... also satisfying the stringent requirements of the central laboratory. A single, multiple-use measurement cartridge contains all of the components of a traditional laboratory analyzer. This long-lasting cartridge includes the sampling unit, all of the sensors and all calibrating reagents.......now available in a state-of-the-art instrument for central or satellite laboratories and clinics.......ntrolled rotation of the femoral component about a central pivot on the tibial component.......oop design, enabling direct heat exchange with the central circulation. The Cool Line combines two important patient care functions: temperature control and central venous catheter capabilities......oop design, enabling direct heat exchange with the central circulation. The Cool Line combines two important patient care functions: temperature control and central venous catheter capabilities......on Management System enabling you to establish one central database for all your department's non-invasive procedures.......ng solution to complement the Envoy. The Ensemble central station completes Mennens system....Infinity MultiView WorkStation
...atient categories. Flexible enough to be used as a central station or as a display in a remote care unit, the MULTIVIEW WORKSTATION shows data collected from INFINITY bedside monitors and INFINITY Telemetry patients. By combining powerful workstation technology with versatile application software, the MULTIV......ess. Send patient tests via email, LAN or WAN to a central analysis location where Philips Zymed Holter analysis applications are used. The streamlined process eliminates the delay and expense associated with couriers and overnight shipping, and reduces staff training needs and equipment maintenance costs.......ed for future screening comparisons, E-mailed to a central patient database for more comprehensive study and/or printed directly to a digital printer for hard copy record keeping....Topcon Remote Tracing Software
...then transfers the order via a telephone line to a central lab. Once all of the information is entered, the o...t a time or batch process to the host terminal, or central edging lab. The Job Summary Screen records the jobs current status. At the lab, the system receives ...SL 130 Biomicroscopic Slit Lamp
...possibility of operating the slit projector in the central position with either the left or right hand. The instrument configuration allows you to use different prism heads and a micromanipulator....High Speed Magnetic Stimulator (HSMS)
... painless method of stimulating the peripheral and central nervous system. Cadwell Laboratories manufactures two magnetic stimulation devices, the MES-10 and the High Speed Magnetic Stimulator (HSMS). The Hight Speed MES-10 magnetic stimulator is capable of stimulation rates up to 25 Hz at full power. Severa...... painless method of stimulating the peripheral and central nervous system. Cadwell Laboratories manufactures two magnetic stimulation devices, the MES-10 and the High Speed Magnetic Stimulator (HSMS). The Hight Speed MES-10 magnetic stimulator is capable of stimulation rates up to 25 Hz at full power. Sev...... macula, its surroundings out to 30 as well as the central vitreous body sections. Easy to use, lightweight glass provides a direct image....EyeCap RI Image Capture and Management System
... of standard systems and can also export data to a central workstation........S. in 1993 to provide contrast enhancement of the central nervous system (CNS) to detect lesions of the brain, spinal cord, and associated tissues. OMNISCAN has since received approval for adult body and high-dose CNS indications, and pediatric CNS and body indications. OMNISCAN comes in different sizes to ...Hoffmann Classic Sterile Wrist Kit
...ng the connecting bar length by turning one of the central wheels against the bar tab on the sliding half of the connecting bar.......system, modular compression/distraction, versatile central body component that provides 360 of rotation, and a positive locking mechanism that provides exceptional holding strength....Kompressor Compression Screw System
...ding" and "trailing" portions of the screw and the central shaft along which the trailing screw travels as it crosses the fracture line. In this manner, the surgeon actually has the ability to "dial-in" the compressive load desired, and to adjust that load intraoperatively....Our perimeters are not restricted to small central fields, unconventional printouts and limited applications. These are full field capable, all encompassing systems and are the only perimeters you'll ever need to ensure the most comprehensive patient care possible. They also include the most importa......ration of the infused fluid. The device also has a central through-lumen that is compatible with a 0.035" gui...ion Wire is exchanged for the guidewire within the central lumen of the catheter. Once placed, the shape-set region of the Dispersion Wire resides between the ...EBI Ionic=® Spine Spacer System
...ferior platforms facilitate bone growth around the central column and are flared outward for greater surface contact. The endplate fins help reduce implant migration. Available in various sizes and lordotic angles....... imaging modalities and information sources in one central system. It simplifies the natural cardiology workf...namic information and waveforms, are acquired in a central database and accessed for viewing and handling on a single computer. Access images and reports on lo......odynamic leverage. All Delta valves incorporate a central reservoir dome, occluders for selective flushing, and a non-metalliic design. The valves are fabricated of dissimilar materials -- polypropylene and silicone elastomer -- reducing the chance of valve sticking and deformation. Radiopaque indicators pr...IOPac Hand-Held Pachymeter (Standard and Advanced)
...ecting established data on the correlation between central corneal thickness and Goldmann tonometry. In addition, physicians can create up to three Custom formulas for individualized correction.......ed in the corneal stroma, outside of the patient's central optical zone, the product reshapes the anterior surface of the cornea. Intacs inserts is composed of two prescription inserts, each having an arc length of 150 degrees. Composed of polymetylmethacrylate, they are available in five thicknesses - .025m......eripheral defects that are not associated with the central field to be explored. Practice Management Integration provides the logical way to streamline your practice. With the Medmont Studio package the practitioner is now able to store perimetry, topography and digital imaging results in a format that is mo...MGS-2 Mini Ganzfeld Stimulator
...m2) allows testing under photopic condition. A red central fixation light is provided.......ility to photograph the corneal endothelium in the central area of the cornea. The model comes with a 9 high-... areas by asking the patient to look away from the central fixation target. Either up or down, or left or right. If you were planning to photograph a great dea...Cellchek CC-7000 with Pachymeter
...he ability to measure the corneal thickness in the central area. The image of the cells is displayed on the 9" monitor, which is supplied with the system. This model is exactly the same as the model CC-5000 with a few very important exceptions. The CC-7000 will also measure the thickness of the cornea. (Pach...ViewPoint CK System (Conductive Keratoplasty)
...CK creates a purse-string effect that steepens the central cornea through a ring of application spots around the periphery of the cornea. Several studies have concluded that the depth of shrinkage determines the degree of corneal correction permanency. Because of the intrastromal delivery of RF energy, CK pr......atment thermally contracts the tissue, causing the central cornea to steepen. A bandage soft contact lens is usually placed on the eye until the following day. They eye may have some irritation for the first few days.......th (NIH) study published in mid-2002, the patients central cornea thickness (CCT) is an important and necessary biometric parameter in risk assessment for this patient population....LSM-12000 High-Magnification Slit-Lamp Biomicroscope
...from you. You can decide what you want to observe: central endothelium, peripheral endothelium, corneal stroma, or lens - you decide what and where to observe and what and where to photograph.......d malignancy, apparently by a direct effect on the central nervous system. Calcitonin secretion is stimulated by increased plasma calcium concentrations, and is also regulated by gastrointestinal peptides, estrogens and vitamin D. Gastric peptide stimulation of calcitonin secretion following a meal may play ...Calcitonin, Ultra-Sensitive RIA Test
...d malignancy, apparently by a direct effect on the central nervous system. Calcitonin secretion is stimulated by increased plasma calcium concentrations, and is also regulated by gastrointestinal peptides, estrogens and vitamin D. Gastric peptide stimulation of calcitonin secretion following a meal may play ...AliMed® Bendable Elbow Orthosis
...can be bent to achieve almost any elbow angle. The central part of the joiner bar extends out so it never contacts the elbow joint.Special attention is paid to the patient comfort, which translates well in compliance. The aluminum cuffs are fully padded with 3/8" of soft, pink T-Foam. The slip-on cover of hi...SZ61/SZ51 Zoom Stereo Microscopes
...ate color. Dependable, high-performance optics are central to the production of consistent, accurate results in todays widening range of biological microscopy applications....BchiVac V-1000 vacuum pump, w/Pump Controller V-719, and automatic change over valve
... ultimate vacuum of 1 mbar Unit can be used as a central vacuum source for the entire lab; no control cables are required from each apparatus, as unit maintains low ultimate vacuum; turns on only when additional vacuum is needed Each separate rotary evaporator, gel dryer, vacuum oven, etc., can run at di...... ultimate vacuum of 1 mbar Unit can be used as a central vacuum source for the entire lab; no control cables are required from each apparatus, as unit maintains low ultimate vacuum; turns on only when additional vacuum is needed Each separate rotary evaporator, gel dryer, vacuum oven, etc., can run at di......ystems as well as the need to transport samples to central facilities for analysis. Fast There's no need to wait hours or days for results on other platforms. With capability to perform extremely rapid heating and cooling cycles, the SmartCycler System can deliver results in as little as 20 minutes. Real......ystems as well as the need to transport samples to central facilities for analysis. Fast There's no need to wait hours or days for results on other platforms. With capability to perform extremely rapid heating and cooling cycles, the SmartCycler System can deliver results in as little as 20 minutes. Real......ystems as well as the need to transport samples to central facilities for analysis. Fast There's no need to wait hours or days for results on other platforms. With capability to perform extremely rapid heating and cooling cycles, the SmartCycler System can deliver results in as little as 20 minutes. Real......ystems as well as the need to transport samples to central facilities for analysis. Fast There's no need to wait hours or days for results on other platforms. With capability to perform extremely rapid heating and cooling cycles, the SmartCycler System can deliver results in as little as 20 minutes. Real......ystems as well as the need to transport samples to central facilities for analysis. Fast There's no need to wait hours or days for results on other platforms. With capability to perform extremely rapid heating and cooling cycles, the SmartCycler System can deliver results in as little as 20 minutes. Real......ystems as well as the need to transport samples to central facilities for analysis. Fast There's no need to wait hours or days for results on other platforms. With capability to perform extremely rapid heating and cooling cycles, the SmartCycler System can deliver results in as little as 20 minutes. Real......ystems as well as the need to transport samples to central facilities for analysis. Fast There's no need to wait hours or days for results on other platforms. With capability to perform extremely rapid heating and cooling cycles, the SmartCycler System can deliver results in as little as 20 minutes. Real......ystems as well as the need to transport samples to central facilities for analysis. Fast There's no need to wait hours or days for results on other platforms. With capability to perform extremely rapid heating and cooling cycles, the SmartCycler System can deliver results in as little as 20 minutes. Real......ystems as well as the need to transport samples to central facilities for analysis. Fast There's no need to wait hours or days for results on other platforms. With capability to perform extremely rapid heating and cooling cycles, the SmartCycler System can deliver results in as little as 20 minutes. Real......ystems as well as the need to transport samples to central facilities for analysis. Fast There's no need to wait hours or days for results on other platforms. With capability to perform extremely rapid heating and cooling cycles, the SmartCycler System can deliver results in as little as 20 minutes. Real......all with impressive sensitivity and correlation to central laboratory analyzers. It's an easy to use, effective tool for professionals at the point-of-care, including laboratories, hospital emergency departments, critical care units and ambulatory services.......atometry by topography will typically overestimate central corneal power in patients who have undergone keratorefractive surgery. With these concerns in mind, Quantel Medical has developed the new Axis II PR (post refractive) biometer. Based upon the patients historical data, doctors can choose from six pos......an be integrated into the Datex-Ohmeda Network for central monitoring. The S/5 Light Monitor also provides for data continuity between care sites with the optional Data Card. The optimal 9" EL screen with clear layout of information and large numbers, the S/5 Light Monitor offers visibility and definition u......Acuity LT allows you to monitor patients at both a central nursing station and at the point of care. Vital signs information is always at your fingertips. And best of all, you are up and monitoring much quicker than with traditional systems. Acuity LT installation requires little or no outside assistance. F...