Navigation Links
Curvature in Medical Products

Contour Gold/Platinum Eyelid Implants

Description:... feature a proprietary three-dimensional design that conforms to the curvature of the ocular globe. The Contour Eyelid Implant is less conspicuous when ... Contour Gold Eyelid Implants 12.7 mm radius of spherical curvature conforms to the shape of the ocular globe Precisely tapered lower ...
Company:MedDev Corp.

Topcon OM-4 Ophthalmometer

Description:... providing precise objective measurements of the corneal radius of curvature plus accurate measurements of the radius of curvature of contact ....
Company:Topcon America Corporation

GALILEI Dual Scheimpflug Analyzer

Description:... Channel Scheimpflug Camera and a Placido Disk. GALILEI combines the advantages of two technologies: Placido imaging furnishes high accuracy curvature data, while Scheimpflug imaging is optimal for precise elevation ....
Company:ZIEMER USA, Inc.

Titanium Illuminated Microscissors: Curved

Description:... Sharp tipped illuminated scissors with a curvature of 12 mm to follow the contour of the retina. For cutting in the plane parallel to the retina, cutting membranes adherent to the retinal surface and ...
Company:Dutch Ophthalmic, USA

Titanium Microscissors: Curved

Description:... Sharp tipped scissors with a curvature of 12 mm to follow the contour of the retina. For cutting in the plane parallel to the retina, cutting membranes adherent to the retinal surface and ...
Company:Dutch Ophthalmic, USA

Tapered Shaft Microscissors: Curved

Description:... Sharp tipped scissors with a curvature of 12 mm to follow the contour of the retina. Instrument shaft tapers to 0.6 mm diameter. For cutting membranes adherent to the retinal surface; ...
Company:Dutch Ophthalmic, USA

Microscissors: Curved

Description:... Sharp tipped scissors with a curvature of 12 mm to follow the contour of the retina. For cutting in the plane parallel to the retina, cutting membranes adherent to the retinal surface and ...
Company:Dutch Ophthalmic, USA

ThinProfile Eyelid Implants

Description:... while providing the same effectiveness as our proven Contour implant. Our ThinProfile Eyelid Implant features a proprietary three-dimensional curvature and precise tapering to produce the thinnest eyelid implant available. An aesthetically pleasing outcome assures patient ....
Company:MedDev Corp.

Contour Design Eyelid Implants (Platinum)

Description:... Implants, available from FCI Ophthalmics, are designed 40% thinner than the original FCI Contour™ Eyelid Implants, providing a sleek, spherical curvature with tapered edges and smoothly rounded corners. The channel-free 1.0 mm holes permit added freedom in suturing position. The overall dramatically ...
Company:FCI Ophthalmics Inc.

Integra Epilepsy Grid Electrodes

Description:... Integra Epilepsy grid electrodes are thin and flexible for easier placement and to conform to the curvature of the cortical surface. Lead tunneling is done using a 14-gauge tunneling needle ....
Company:Integra LifeSciences Corporation

Orbscan IIz Anterior Segments Analysis System

Description:... the Orbscan II acquires over 9000 data points in 1.5 seconds to meticulously map the entire corneal surface (11 mm), and analyze elevation and curvature measurements on both the anterior and posterior surfaces of the ....
Company:Bausch & Lomb Storz

Digital Binocular Radiusgauge

Description:... a standard or digital display as well as in either monocular or binocular form. All offer the functions of two instruments in one, measuring both the curvature and thickness of contact lenses on a single instrument. The accuracy of both measurements is increased through the 100x magnification and a coaxial ...
Company:Marco Ophthalmic, Inc.

Monocular Radiusgauge

Description:... a standard or digital display as well as in either monocular or binocular form. All offer the functions of two instruments in one, measuring both the curvature and thickness of contact lenses on a single instrument. The accuracy of both measurements is increased through the 100x magnification and a coaxial ...
Company:Marco Ophthalmic, Inc.

Foundation Total Shoulder System

Description:... canal flare index. A/P and lateral fins with holes for suture attachment and rotational stability. Proximal medial hole, humeral / glenoid diametral curvature mismatch for optimizing natural joint translation. Rough textured proximal surface to provide enhanced proximal fixation. Distal grooves for ...
Company:Encore Medical Corporation

KR-8100PA/P Auto Refractometer

Features:... 10 placido rings (in case of R=8 mm). BASE curvature ADVICE Based on the mapping data, the KR-8100PA/8100P advises the base curvature (BC) for the contact lens. This is done for ... the helpful function that indicates the base curvature and eccentricity for contact lens fitting ...
Company:Topcon America Corporation

Blinkeze™ External Lid Weights

Features:... Produced from 99.99% pure tantalum 12.7 mm radius of cylindrical curvature conforms to the curvature of the eye Treatment kit contains 100 hypoallergenic adhesive strips ...
Company:MedDev Corp.

Livewire Spiral HP™ Catheters

Features:... 20 bipolar-spaced electrodes Circular tip Ergonomic handle Automatic steering lock tip curvature in place without backlash. Reduces unwanted tip movements. No need to exert continuous force to maintain tip curve Patented steering handle ...
Company:St. Jude Medical, Inc.

Microscissors: Eckardt Vertical Retinomy Scissors

Features:... Vertical scissors with small curved blades. 12 mm. curvature follows the contour of the retina. Ideal for any procedure requiring a partial to 360 retinotomy, including macular rotation, severe PVR, or ....
Company:Dutch Ophthalmic, USA

TMS-4 Corneal Topographer

Features:... Range 33.75D 61.36D Minimum Scale Interval 0.1D Map Type Options Instantaneous Radius of curvature (Tangential), Refractive, Height (Enhanced & Differential) Map Type Options Single, Dual, Multiple, Differential, ...
Company:Tomey Corp.

RT-6000 Auto Ref-Topography

Features:... Measurement Steps: Sphere: 0.12D Cylinder: 0.12D Axis: 1 Corneal curvature Measurement: 0.01 mm Corneal Shape Measurement: 0.2D Minimum Pupil Diameter: 2.5mm ...
Company:Tomey Corp.

NexGen® Complete Knee Solution Cruciate Retaining (CR)

Features:... PMMA precoat, and non-coated versions. Anterior flange thickness. Distinctive Zimaloy® cobalt-chromium-molybdenum alloy. Different radii of curvature in the sagittal plane. CR articular surface options. ...
Company:Zimmer Orthopedics

MJS™ Anatomic Knee System

Features:... down with any size tibial component without compromising the centerline of the condyles. Closely resembles the anatomic centers and radius of curvature for articulation with the tibia. Deepend patellar groove and raised lateral condyle to avoid functional shortening of the extensor tracking and ...
Company:Encore Medical Corporation

Epik® Uni-System

Features:... Femoral Component 4 Sizes Anatomic Design - Left Medial/Right Lateral and Right Medial/Left Lateral Coronal curvature reduces edge wear Anatomic sagittal curvature 6 inclination improves contact area through complete ROM Anterior Angled Peg Low-profile keel Thin ...
Company:Encore Medical Corporation

3DKneeTM System

Features:... Femoral Component: Congruent Lateral Condyle Deepened Patella Groove Wide Medial Condyle Single Radius curvature for increased contact area up to 80 Domed Patella: Domed Geometry for optimal contact area with the deepened trochlear groove Available in ...
Company:Encore Medical Corporation

AL-3000 A-Scan Unit

Features:... IOL power is calculated automatically after entering the corneal curvature data & the desired postoperative refraction. Immersion Cap is easy-to-use & disinfect. High resolution color touch screen display provides a simple ...
Company:Tomey Corp.

Carpentier-McCarthy-Adams IMR ETlogix Annuloplasty Ring

Features:... with Type IIIb mitral regurgitation. Decreased anteroposterior (AP) distance increases leaflet coaptation. Asymmetric 3-D reduced P2-P3 curvature design compensates for tethered P3 segment. Increased sewing margin in the P2-P3 region, marked with suture, designed to accommodate a ...
Company:Edwards Lifesciences Corporation

Zyoptix Diagnostic Workstation

Features:... Measures higher order aberrations through the 5th order Analyzes elevation and curvature measurements on both anterior and posterior surfaces of the cornea Capable of detecting and analyzing posterior corneal abnormalities where some ...
Company:Bausch & Lomb Storz

NexGen Complete Knee Solution Cruciate Retaining (CR)

Features:... metal, PMMA precoat, and non-coated versions. Anterior flange thickness. Distinctive Zimaloy cobalt-chromium-molybdenum alloy. Different radii of curvature in the sagittal plane. CR articular surface ....
Company:Zimmer, Inc.

Craniofix Titanium Burr Hole Clamp

Features:... Fits securely into the cranial burr hole. Specially designed disks allow for drainage. curvature of lower disk seats into burr hole. Fast and easy application. Provides optimal stability. Reliable fixation of the bone ....
Company:AESCULAP

KR-8000PA SUPRA Auto-Kerato Refractometer

Features:... Automatic fogging as method of relaxation. Minimal pupil diameter. Corneal curvature radius. Automatically turns off when left unused for 10 minutes which save energy. Special IOL switch to adjust to circumstances of IOL wearers. ...
Company:Topcon America Corporation

Microphthalmic Plate Molteno Implant (M1)

Features:... This is a mini version (plate diameter 8mm) of the Single Plate Molteno Implant with a reduced radius of curvature suitable for microphthalmic ....
Company:Molteno Ophthalmic Limited
Other Contents
(Date:8/21/2014)... heard of the water window? It consists of radiations ... not absorbed by the water in biological tissues. New ... coherent radiations within the water window. These could be ... high-contrast image of the biological samples or to be ... identifies the physical mechanism needed to efficiently generate the ...
(Date:8/21/2014)... RUSTON, La. A team of researchers ... innovative method for using affordable, consumer-grade 3D ... implants that can contain antibacterial and chemotherapeutic ... team comprised of doctoral students and research ... nanosystems engineering programs collaborated to create filament ...
(Date:8/20/2014)... E. Fox, a John and Rebecca Moores Professor of Biology ... a fellow in the International Society for the Study of ... of four members two from the U.S., one from ... 2014. Fellows are elected every three years, and 36 have ... more than 20 countries, the ISSOL includes researchers from disciplines ...
Breaking Biology News(10 mins):Water window imaging opportunity 2Louisiana Tech University researchers use 3D printers to create custom medical implants 2Louisiana Tech University researchers use 3D printers to create custom medical implants 3UH professor named fellow by International Astrobiology Society 2
(Date:8/22/2014)... 2014 The regional economy is about ... is on the grow again. The plant will ... 2016 to boost production of the popular Highlander midsize ... overall investment to $4 billion. This step allows Toyota ... additional flexibility to adjust its product mix to meet ...
(Date:8/22/2014)... Americans know little about how Ebola is transmitted and harbor ... United States, a new survey shows. About four in ... a major Ebola outbreak in the United States, and one-quarter ... get sick with the deadly virus in the next year, ... However, those opinions don,t match reality, the Harvard researchers ...
(Date:8/22/2014)... Las Vegas, NV (PRWEB) August 22, 2014 ... that teaches readers how they can use natural methods ... for years has caught the attention of Shane Michaels, ... only a condition that affects the skin, it can ... suffer from it,” reports Michaels. “The intense itching and ...
(Date:8/22/2014)... Epidermal growth factor receptor (EGFR) mutations found in ... of advanced non-small cell lung cancer (NSCLC) patients correlates ... DNA. , EGFR tyrosine kinase inhibitor (TKI) therapy is ... NSCLC, but the standard for determining mutation status is ... be limited or not available. A more abundant and ...
(Date:8/22/2014)... August 22, 2014 Advancements in ... some clinical applications due to their cost-effectiveness, non-invasiveness, ... innovations in ultrasound, such as the evolution of ... to keep the market moving throughout 2014 and ... can enhance not only the point-of-care (POC) testing ...
Breaking Medicine News(10 mins):Health News:Toyota Indiana Adding 300 Jobs to Build More Highlanders 2Health News:Many Americans Harbor Unfounded Fears About Ebola Outbreak: Survey 2Health News:Beat Eczema: Review Exposes Susan Clark’s Guide to Curing Eczema Naturally 2Health News:High concordance between EGFR mutations from circulating-free tumor DNA and tumor tissue in non-small cell lung cancer 2Health News:Global Top Ultrasound Market Suppliers Assessed in New VPG Research Report Available at MarketPublishers.com 2Health News:Global Top Ultrasound Market Suppliers Assessed in New VPG Research Report Available at MarketPublishers.com 3
Other TagsOther Tags