Shimadzu Phoretix Pro upgrade from Shimadzu Biotech
Description:... advanced statistical tool sets for gel and spots comparison and queries (including finding ... MDS or CA). Answers questions such as Which spots are similar and/or different in a single ... similar between different experiments? Which spots are similar between different experiments? How ...ArrayControl RNA Spikes from Ambion
Description:... PCR Spots, Oligo spots and complementary RNA Spikes for the normalization and control of ... stringency and background. Normalize Cy3 and Cy5 signals. Control PCR spots and Oligo Spots, and complementary RNA Spikes for the normalization and ...VersArray ChipWriter Pro System, 220-240 V from Bio-Rad
Description:... This system can generate high-density arrays with greater than 80,000 spots per glass slide or greater than 57,000 spots per membrane with a capacity of 126 standard microarray slides (25 x 75 ...VersArray ChipWriter Pro System With Colony-Picking Capabilities, 110-120 V from Bio-Rad
Description:... This system generates high-density arrays with greater than 80,000 spots per glass slide or greater than 57,000 spots per membrane with a capacity of 126 standard microarray slides (25 x 75 ...PROTEINEER sp: Automated Spot Picker from Bruker Daltonics
Description:... remaining two racks. The software allows for manual selection of single spots by mouse-click on the scanned gel image. The individual x,y-coordinates, ... Excel spreadsheet. PROTEINEER Suite Integration Gel and excised gel spots are identified via electronic transponders mounted on the gel frame and ...MicroVigene from VigeneTech, Inc.
Description:... fitting background correction and dust removal, enhancing the accuracy of spots quantification. Modulated quantitative and qualitative protein array data ... a single end-to-end solution. The final result, the original image, spots quantification and reference curve are all in a single screen for easy ...DeStreak Reagent from GE Healthcare, formerly Amersham Biosciences
Description:... DeStreak Reagent, 1 ml. Improves reproducibility and quality of 2-D gels by preventing streaking.Eliminates extra spots caused by nonspecific oxidation of proteins.Stabilizes proteins throughout entire 2-D runs, ensuring simplified, well-resolved protein ...PS20 and RS100 preactivated ProteinChip Arrays from Ciphergen
Description:... the same binding chemistry as the former PS1 array, but with an updated hydrophobic barrier coating. These arrays are 8 spot chips with 2 mm diameter spots spatially compatible with one column of a standard 96-well microplate (9 mm well pitch). Typical applications include immunoassays, receptor-ligand ...2-D MARKER from Pierce Biotechnology, Inc.
Description:... selected to give a useful range of molecular weight and pI coverage. Proteins were selected that give a variety of features from tight single spots to characteristic charge trains to aid the analyst in gel orientation. Molecular weights range from 17K to 80K, with pI values ranging from 4.5 to ...Multi - Organ Tissue - Arrays from Dominion Pharmakine S.L.
Description:... A collection of 42 spots with normal tissues from different organs of C57 mice, rat and ....Shimadzu Phoretix 2D Evolution from Shimadzu Biotech
Description:... has been used to differentiate between samples is to consider the application of different dyes to the gel. Each stain is applied to the sample and spots are specifically detected at different wavelengths. Cross stain analysis (CSA) supports multiplexed gel analysis and differential staining ...Shimadzu Phoretix 2D from Shimadzu Biotech
Description:... spot detection algorithm and quantitation even for low intensity spots A precise and accurate spot detection algorithm designed specially for ... picking robot. Tables and image views dynamically linked to display spots of interest and record expression change. Automatic matching, with the ...UNIchip AV-400 Premium from Protagen AG
Description:... or the protein biochips can be used directly for off-target activity testing without any further processing. In the premium version, Protagen also spots one or several customer specific antigens (proteins) onto the microarray allowing for quantitative ....UNIchip AV-VAR IP Premium from Protagen AG
Description:... or the protein biochips can be used directly for off-target activity testing without any further processing. In the premium version, Protagen also spots one or several customer specific antigens (proteins) onto the microarray allowing for quantitative ....UNIchip AV-VAR EP Premium from Protagen AG
Description:... or the protein biochips can be used directly for off-target activity testing without any further processing. In the premium version, Protagen also spots one or several customer specific antigens (proteins) onto the microarray allowing for quantitative ....Protein Identification Service via MALDI MS/MS from Protagen AG
Description:... This protein identification Service includes 1. Scanning of gel(s) 2. Excision/picking of protein spots 3. High-sensitive tryptic in-gel digestion and peptide extraction 4. Preparation of samples for MALDI-MS 5. Acquisition of PMF (Peptide Mass ...GenePix Pro from Universal Imaging Corporation (a subsidiary of Molecular Devices)
Description:... and analysis features ensure the most accurate results from both rectangular and hexagonal (orange-packed) arrays, whether they contain just a few spots or entire genomes. Select automation options for speedy one-touch scanning and analysis, or relax and explore your data using a wide range of ...GenePix Pro Microarray Image Analysis Software from Molecular Devices
Description:... and analysis features ensure the most accurate results from both rectangular and hexagonal (orange-packed) arrays, whether they contain just a few spots or entire genomes. Select automation options for speedy one-touch scanning and analysis, or relax and explore your data using a wide range of ...HybArray 12 DNA hybridization system from PerkinElmer
Description:... of hybridization areas, the standard area of 18mm by 56mm, or the larger area of 21mm by 68mm. The larger area allows researchers to print more spots on the slide without being restricted to conducting the hybridizations by the manual method. With this increased flexibility, the HybArray 12™ ...