Varian 820-MS from Varian, Inc.
... system and patented Turner Interlaced Coils break down the toughest sample matrices, reduce matrix effects, and minimize ion energy spread for maximum sensitivity and stability. Patented 90 degree ion mirror and low noise doubleoff-axis quadrupole provide industry leading sensitivityand background. A...Qpatch HT from Sophion Bioscience
...red to the on-board centrifuge where they are spun down and resuspended in the extracellular ringer solution to a concentration that ensures optimal success rates. Elevator units for stacking and feeding compound plates and QPlates are featured in the QPatch HT. Together with the cell preparation station,......ts of a photodiode array sensor with pixel spacing down to 48 microns. All models are available in low x-ray energies (10-50 kV) and an extended energy range (10-160 kV). Applications range from medical diagnostics and scientific imaging to veterinary medicine and industrial inspection (NDT). All models a...BioSafe Clean Room; 304 Stainless Steel from Terra Universal, Inc.
...create ultra-smooth surfaces that are easy to wipe down and disinfect. One-inch radius corners simplify cleaning. Unique double-wall panel design creates strong, rigid surface without external bracing. Accommodates flush-mount control panel and utility options. Optional ceiling HEPA filter/fan units, ligh...BioSafe Clean Room; Powder-Coated CR Steel from Terra Universal, Inc.
...create ultra-smooth surfaces that are easy to wipe down and disinfect. One-inch radius corners simplify cleaning. Unique double-wall panel design creates strong, rigid surface without external bracing. Accommodates flush-mount control panel and utility options. Optional ceiling HEPA filter/fan units, ligh...BioSafe Powder Containment Room from Terra Universal, Inc.
...create ultra-smooth surfaces that are easy to wipe down and disinfect. One-inch radius corners simplify cleaning. Unique double-wall panel design creates strong, rigid surface without external bracing. A supplemental CLeanZone Recirculation System provides a particle-free processing zone and draws exhaust...FLUOstar OPTIMA Multifunction Microplate Reader from BMG LABTECH
...a high resolution in regions of interest, and slow down in areas of relatively little change. Multi-color detection The FLUOstar OPTIMA can be used to measure up to eight fluorophores/chromophores per well allowing you to perform 260 nm / 280 nm, SNPs, and other multichromatic assays easily. And, due t...Thermostable dUTPase from GenScript Corporation
...oduct, proofreading polymerases to stall and slows down non-proofreading polymerases such as Taq. The dUTPase increase in PCR product yield, length and fidelity enables further down-stream applications. These effects make dUTPase useful in PCR fidelity and yield-sensitive applications such as cloning an...LUMIstar OPTIMA Microplate Reader from BMG LABTECH
... to 250 kinetic points at specified time intervals down to the millisecond range. Top and bottom reading The reader has top and bottom optic reading capability. Cell-based assays are closer to the bottom optics, therefore allowing more sensitive measurements. It is also possible to inject into a 384-well ...Varian 810-MS from Varian, Inc.
... system and patented Turner Interlaced Coils break down the toughest sample matrices, reduce matrix effects, and minimize ion energy spread for maximum sensitivity and stability. Patented 90 degree ion mirror and low noise doubleoff-axis quadrupole provide industry leading sensitivityand background. A...jetSI conc. 10 mM from Polyplus Transfection
... and B.-A. Demeneix. Lipid-mediated siRNA delivery down regulates exogenous gene expression in the mouse brain at picomolar levels. J. Gene Med., 2005, 7, 198-207....T7 RNA polymerase from Chimerx
...s in vitro transcripts from almost any DNA that is down stream from a T7 promoter. Transcripts can be used as hybridization probes, templates for in vitro translation, substrates in RNA processing systems, or for exon and intron mapping of genomic DNA....Lysozyme Fluorometric (Green) Assay Kit, EnzChek® from Molecular Probes (Invitrogen)
...uorescence-based assay can detectlysozyme activity down to 20 U/mL (Figure 1). The assaymeasures lysozyme activity on Micrococcus lysodeikticus cellwalls, which are labeled to such a degree that the fluorescenceis quenched. Lysozyme action can relieve this quenching,yielding a dramatic increase in fluores...LabWorks Analysis Software from UVP
...ed analysis package designed with easy to use drop down menus yet sophisticated and powerful functionality. Image acquisition interface is compatible with dozens of CCD cameras for easy image capture. Sequential and dynamic integration Automated Digital Video Playback Saturation Warning Single Butt...Amylase Fluorometric (Green) Assay Kit, EnzChek® from Molecular Probes (Invitrogen)
...ssayKit could be used to detect a-amylase activity down to a finalconcentration of 2 10-3 U/mL, where one unit is defined as theamount of enzyme required to liberate 1 mg of maltose fromstarch in 3 minutes at 20C, pH 6.9....Amylase Fluorometric (Green) Assay Kit, EnzChek® from Molecular Probes (Invitrogen)
...e, the assay can detectthe activity of this enzyme down to a final concentration of1 10-4 U/mL (0.3 g protein/mL), where one unit is defined asthe amount of enzyme required to liberate 1 mg of maltose fromstarch in 3 minutes at 20C, pH 6.9. At high enzyme concentrations(e.g. 2 mU/mL and higher), incubati...DNA120 OP SpeedVac System from Thermo Scientific
...OP is specifically engineered for efficient drying down of synthetic oligos. Its sturdy design incorporates a glass cover and a post-trap with ammonia neutralizing solution for fully automated, unattended, odor-free processing of samples in ammonium hydroxide. Complete Concentration/Drying System for Sy......h a 3/8 beta blocking acrylic cover Cover swings down for easy access to the bottle carousel Carousel pops out of chamber for easy insertion or removal of bottles Dimensions: 9"H x 13"W x 8"D...... spilled media Adjustable RPM knob lets you slow down the rotary wheel for removal of samples The rotary wheel can hold twenty (20) 35 x 150mm, ten (10) 35 x 300mm at the same time Stainless steel internal construction Multiple bottle sizes, arrangements and off-set bottle positions (three bottle s...HEEBO Human Genome Set 200 pmol from Invitrogen
...als to resuspend the oligos; plates should be spun down prior to removing seals, and seals should be removed slowly....GeneTraffic from Iobion Informatics
... Low Investment, High Return : Weve kept the cost down by building GeneTraffic on the solid, reliable Ope...uter. This approach keeps the cost of the software down and support and maintenance issues low. You can focus on the biological aspects of your Microarray r......+60C Optional active cooling allows temperatures down to 10C below ambient (at maximum ambient of +32C) Maximum capacity: four 3000 ml Erlenmeyer flasks Internal spill tray as standard Programmable process parameters: time, temperature and rpm up to 5 programs...Reacti-Bind White Opaque 96-Well plates from Pierce Biotechnology, Inc.
...ing strip loss while in use even if turned upside down Strip guides help to avoid misorientation of the strip when returned to the holder Strips are gently removed from the frame with a strip well ejector Wells can be easily separated from the strips with a gentle twist, allowing you to work wit...Tube Rotator from Barloworld Scientific Ltd
... be used in incubators up to 60C and in cold rooms down to 4C. The rotator has a variable speed of 2 to 40rpm for gentle rolling or vigorous mixing of samples and the angle of rotation is fully adjustable, from horizontal for minimal mixing to vertical for full end-over-end mixing. A digital timer and spe...Nanoject II, 220 VOLT from Drummond Scientific Company
...oduction of the Nanoject II offers volumes ranging down to 2.3 nL. and up to 69nL. with a higher torque motor. This new motor is quieter and smoother in operation further reducing tip movement. The development of new collet configuration will hold the micropipet more securely and thereby reduce air infilt......itable for PCR (requires the pressure from a screw down heated lid), especially 384-well formats where piercing is a useful method for sample retrieval. Multiple seals can be applied over the existing seal. Ideal for compound management and high throughput screening applications....Reacti-Bind 8-Well Strip plates Corner Notch from Pierce Biotechnology, Inc.
...ng strip loss while in use - even if turned upside down Strip guides help to avoid misorientation of the strip when returned to the holder Strips are easily and gently pried from the frame with a unique strip ejector tool Wells can be easily separated from the strips with a gentle twist, allowing you t...N5 Submicron Particle Size Analyzer - 230V from Beckman Coulter
... nondestructive method for measuring particle size down to a few nanometers, and the N5 is the only commercially available PCS analyzer that won't leave you wondering whether or not you really know what's in your sample. Only multi-angle PCS analysis can reveal more accurately all the particle populati...N5 Submicron Particle Size Analyzer - 115V from Beckman Coulter
... nondestructive method for measuring particle size down to a few nanometers, and the N5 is the only commercially available PCS analyzer that won't leave you wondering whether or not you really know what's in your sample. Only multi-angle PCS analysis can reveal more accurately all the particle populati...HIV Volume 2 (Biochemistry, Molecular Biology and Drug Discovery) from Promega
...CD4 interactions; transient assays for Nef-induced down regulation of DC4 expression; Vpu and Vif; cellular assays for anti-viral drugs and gene therapy....In Vivo Perfusion System (Rat Version) from AutoMate Scientific, Inc
...up, use and clean--Complete system with everything down to the needles. Fits in standard hoods....MX80 Series Miniature Precision Stages from Parker Hannifin Corporation
...e creep cross-roller bearings, encoder resolutions down to 10 nanometers, integrated home/ limit switches, and high-flex cabling. Miniature size; low profile Accelerations to 5 gs Velocities to 2 m/s Fast settling; smooth translations Cleanroom and low-ESD options Dowel holes provided for precise pa...13(S)-HODE-d4, Deuterium Conjugated/Tagged from Cayman Chemical
...othelium at concentrations around 1 µM, and down regulates the expression of the IRGpIIb/IIIa receptor....13(S)-HODE-d4, Deuterium Conjugated/Tagged from Cayman Chemical
...othelium at concentrations around 1 µM, and down regulates the expression of the IRGpIIb/IIIa receptor....