Date:6/29/2010

Adding a continuous blood sugar level sensor to an insulin pump helps patients with type 1 diabetes achieve better blood sugar control compared to the common standard of care, multiple daily insulin injections, concludes a study published on-line today in the New England Journal of Medicine.

The paper is entitled, Effectiveness of Sensor-Augmented Insulin-Pump therapy in Type 1 Diabetes.

"Combining the best technologies for insulin delivery and blood sugar monitoring really pays off for diabetes control," says Dr. Bruce Perkins, one of the co-authors of the study, endocrinologist at Toronto General Hospital and Assistant Professor at the University of Toronto. "Being aware of continuous blood sugar trends and having the tools to do something about them can help committed patients of all ages self-manage their diabetes very well."

Research conducted at 30 centres across North America, including Toronto General Hospital, found a significant decrease in average blood sugar levels (or A1c levels, which measure the average blood sugar levels over the past two or three months) from a baseline of 8.3% to 7.5% in the group using sensors and insulin pumps, compared to 8.3% to 8.1% in the multiple daily injection group, at one year. The decrease in A1c levels in both adults and children occurred without an increase in the rate of severe hypoglycemia, or low blood sugar, a common problem among patients who are trying to achieve better control of their blood sugar. Symptoms include shakiness, rapid heart beat, confusion and even unconsciousness.

Moreover, the proportion of participants who reached the A1c target of 7% or less was greater in the pump-therapy group than in the injection-therapy group. Adults with diabetes try and maintain A1c levels of seven percent or below in order to reduce the risk of complications from diabetes, such as kidney failure, heart disease and blindness.

The 485 study participants with inadequately controlled type 1 diabetes ranged in ages from seven to 70, and were treated for at least one year, in a randomized, controlled trial.

In the study, patients in the sensor-augmented pump therapy arm used an integrated system which incorporates an insulin pump, continuous glucose monitor and self-management software. A glucose (sugar) sensor reveals fluctuations in glucose levels in real-time, and transmits electric signals wirelessly to the insulin pump, which is about the size and shape of a small cell phone. The pump displays the blood sugar levels, allowing patients to react to either high or low levels before they become dangerous.


'/>"/>

Contact: Alex Radkewycz
alexandra.radkewycz@uhn.on.ca
416-340-3895
University Health Network
Source:Eurekalert

Related medicine news :

1. New method manipulates particles for sensors, crime scene testing
2. Nanotech breath sensor detects diabetes and potentially serious complication
3. Long-lasting sensory loss in WTC workers
4. Loadstar Sensors Releases LoadVUE-1000 Load Cell Software with Logging, Plotting and Alerting features
5. Biosensor chip enables high-sensitivity protein analysis for disease diagnosis
6. Loadstar Sensors Announces New Website for its Innovative Digital Load Cell Solutions
7. Immune sensors suppress colitis-associated cancer
8. New Sensors Stick to Organs to Monitor Health
9. HOGGAN Ergo to Debut New Software and Sensor at the 2010 Applied Ergonomics Conference
10. Carnegie Mellon will test ability of embedded sensors to detect onset of dementia, infirmity
11. MainStreet MD Launches Personal Safety Solutions for Children and Seniors Built On SensorLogic's Cloud Computing Platform
Post Your Comments:
*Name:
*Comment:
*Email:
(Date:5/27/2016)... ... May 27, 2016 , ... Aimed at nurses and ... stories, which come courtesy of leaders in the nursing and health care industry. It ... advocates and associations—namely Abilene Christian University. , As the nursing industry is coming ...
(Date:5/26/2016)... ... May 26, 2016 , ... Despite last week’s media reports hinting ... and company to wait until March 2017 for an interest rate increase, according to ... College of Business. , “The Federal Open Market Committee (FOMC) dot charts are of ...
(Date:5/26/2016)... ... May 26, 2016 , ... ... thousands of defective respirators, according to court documents and SEC filings. A ... and Becky Tyler v. American Optical Corporation, Case No. BC588866, Los Angeles County, ...
(Date:5/26/2016)... ... ... Connor Sports, through its Connor Cares initiative, will continue to expand ... Tour that will commemorate the Indiana Fever legend’s hall-of-fame career and final WNBA ... levels of the game, Connor Sports has committed to a significantly increased focus on ...
(Date:5/26/2016)... (PRWEB) , ... May 26, 2016 , ... ... one that has a significant negative impact on long-term patient survival, reports a ... The results, published online this week in the Journal of Thoracic and Cardiovascular ...
Breaking Medicine News(10 mins):
(Date:5/25/2016)... FDA 510(k) clearance covers ... for urological and surgical applications Mauna ... Cellvizio®, the multidisciplinary confocal laser endomicroscopy (CLE) platform, ... US with the 12 th 510(k) clearance ... This new FDA clearance covers Confocal Miniprobes indicated ...
(Date:5/25/2016)... May 25, 2016  Zymo Research Corp. announced ... new reference materials that help researchers obtain the ... to analyses. The rapid growth of the study ... to have standard methods to improve the reproducibility ... inherently exist at every step of the measurement ...
(Date:5/25/2016)... , May 25, 2016  Granger Diagnostics today ... test for wounds and infections. This test ensures ... and select viruses. The test requires only a ... David G. Bostwick , MD, ... to facilitate wound healing: "We are excited to ...
Breaking Medicine Technology: