New Software for Defibrillators Lowers Risk of Unnecessary Shocks
Date:9/28/2010

By Madonna Behen
HealthDay Reporter

MONDAY, Sept. 27 (HealthDay News) -- Implantable cardioverter defibrillators (ICDs) have saved the lives of tens of thousands of Americans at risk for sudden cardiac death because of serious heart rhythm abnormalities.

But these medical devices have gotten a bad reputation in recent years, mainly because the electrical wires, or leads, that connect the ICD to the heart can sometimes fracture, causing patients to unnecessarily receive painful shocks.

Now, a new study suggests that doctors can cut the relative risk of accidental shocks in half simply by downloading upgraded software into the ICD during a routine office visit.

The Lead Integrity Alert (LIA) software checks the device for suspicious electrical signals six times a day, and if problems are detected, alerts the patient with an audible beep every four hours, according to the study, which was published in the Sept. 27 issue of Circulation.

In contrast, standard ICD software usually monitors the device for signs of fractures and other mechanical problems just once a day, and notifies the patient of any abnormalities with a single alert at the same time every day.

The biggest advance, said study author Dr. Charles Swerdlow, a cardiac electrophysiologist at the Cedars-Sinai Heart Institute in Los Angeles, is that LIA software can detect electrical changes that signal a wire fracture and recalibrate the device to delay an inappropriate shock from occurring.

"The software basically makes the devices less trigger-happy," said Swerdlow, who is a clinical professor of medicine at the University of California, Los Angeles' David Geffen School of Medicine.

The study was funded by Medtronic Inc., which developed the LIA software for use with the company's ICDs that are connected to a specific type of lead that has been particularly prone to fractures. (That lead, known as Sprint Fidelis, was removed from the market in 2007.)

"Some doctors have been pulling these leads out prophylactically because they're worried about fractures, but what they often don't consider is that there are significant risks associated with lead replacement surgery," noted Swerdlow, who added that he hoped these findings encourage doctors to consider other options before replacing ICD leads.

Earlier this year, researchers reported that a new type of ICD that can be implanted just under the patient's skin and eliminate the need for electrical leads altogether may be just as effective as conventional models, but electrophysiologists say larger and longer-term studies are needed to prove their safety and efficacy.

For the software study, Swerdlow and his co-authors compared the experience of 426 patients prior to surgery to replace fractured leads. Half of the patients received standard daily monitoring and half were monitored with the addition of the downloadable LIA software. Among the patients who had standard monitoring, 70 percent received one or more inappropriate shocks, compared with only 38 percent of those who were monitored with the help of LIA software. Five or more inappropriate shocks were delivered to 50 percent of the patients who received standard monitoring, but only 25 percent of patients with LIA.

The researchers also found that 72 percent of patients with LIA had no inappropriate shock, or had at least three days warning prior to an inappropriate shock, compared with only 50 percent of those who received standard monitoring.

Many electrophysiologists began using the software soon after the FDA approved it in August 2008, said Dr. Andrea M. Russo, director of Cardiac Electrophysiology and Arrhythmia Services at Cooper University Hospital in Camden, N.J.

"Inappropriate shocks are much more damaging, psychologically, [than necessary electrical jolts] so we need to aim to eliminate every shock that's unnecessary," said Russo, who is a professor of medicine at UMDNJ-Robert Wood Johnson Medical School in New Brunswick, N.J.

Now that more and more patients with ICDs can be monitored at home with the use of remote systems that send information to doctors over a telephone line, "getting patients to come into the office so we can download the software is sometimes the hardest part," said Russo.

Swerdlow said other ICD software now under development will hopefully making the device "smart enough to know when a lead is broken and withhold a shock altogether." But that advancement, he said, "is a much trickier thing because the penalty for being wrong is really high. If someone crashes their iPod, they're out of songs for a while. But if a patient crashes their defibrillator, they can die."

An estimated 114,000 patients have surgery to implant or replace ICDs every year, according to the American Heart Association.

More information

For more on ICDs, visit the American Heart Association.

SOURCES: Charles Swerdlow, M.D., cardiac electrophysiologist, Cedars-Sinai Heart Institute, and clinical professor, medicine, David Geffen School of Medicine, University of California, Los Angeles; Andrea M. Russo, M.D., director, Cardiac Electrophysiology and Arrhythmia Services, Cooper University Hospital, Camden, N.J., and professor, medicine, UMDNJ-Robert Wood Johnson Medical School, New Brunswick, N.J.; Sept. 27, 2010, Circulation


'/>"/>
Copyright©2010 ScoutNews,LLC.
All rights reserved  

Related medicine news :

1. Research aims to improve speech recognition software
2. Kinnser is First Home Health Software Provider to Utilize the iPad for Point of Care Connectivity
3. FileHold Document Management Software Announces Significant Enhancements and Support for all New Microsoft Platforms
4. Vedero Software Announces Partnership with Smart Energy Cloud for Automated Demand Response
5. Search Technologies Partners with Rocket Software to Provide Expert Support for Folio and NXT Products
6. Agilis Solutions Launches Ask Eileen! Online Q&A Column Answers Questions on Cloud, SaaS, Software Development and Outsourcing Issues and Trends
7. AllMed Launches First-Level Physician Review Workflow Software: MedCert
8. Shadow Technology Slashes Cost of IP Call Management Software By $450 for 5 Channels
9. FileHold Document Management Software welcomes Click2ScanLtd. as a Value Added Re-sellers in the UK
10. Perceptive Software Announces Successful Participation in Integrating the Healthcare Enterprise (IHE) Connectathon
11. IEEE Computer Society Rolls Out Assessment Courses for its CSDA and CSDP Software Development Certification Exams
Post Your Comments:
*Name:
*Comment:
*Email:
Related Image:
New Software for Defibrillators Lowers Risk of Unnecessary Shocks
(Date:2/13/2016)... ... , ... Valentine’s Day is nearly upon us, and most singles could probably ... flawless hair, and a sparkling personality are all well and good, but if somebody ... home with Rover. (Actually, man’s best friend might not even want to be near ...
(Date:2/13/2016)... ... February 13, 2016 , ... In its newly ... vein visualization technology should be used to ensure patient safety when placing an ... INS Standards mandate the use of vein visualization technology in patients with difficult ...
(Date:2/12/2016)... ... 12, 2016 , ... According to an article published February 4th ... significant portion of hernia repairs throughout the United States. Commenting on this article, Beverly ... that this trend has not only been expected, but it seems to be a ...
(Date:2/12/2016)... ... February 12, 2016 , ... CDRH Enforcement Trends: , Back to the Future , ... , As Winston Churchill said, “Those who don’t learn from history are doomed to ... expect when they come knocking this year. But that takes time. , Take a ...
(Date:2/12/2016)... ... February 12, 2016 , ... T.E.N., a ... closed for the ISE Southeast Awards 2016. Finalists and winners of the ISE® ... Southeast Executive Forum and Awards Gala on March 15, 2016 at the Westin ...
Breaking Medicine News(10 mins):
(Date:2/12/2016)... February 12, 2016 ... vermerkt)   http://www.sedar.com ) und ... abrufbar.    --> http://www.sedar.com ... http://www.telestatherapeutics.com abrufbar.    --> ... heute seinen Konzernabschluss des zweiten Quartals ...
(Date:2/12/2016)...  Memorial Hermann Health System has teamed up with ... bring a one-of-a-kind experience to pediatric patients at ... as 360-degree video and Google Cardboard, Howard was able ... giving the patients and their families an unexpected, and ... on video . Memorial Hermann IRONMAN ...
(Date:2/12/2016)... , Feb. 12, 2016  Eli Lilly and Company ... Court decided the Alimta® (pemetrexed disodium) vitamin regimen patent would ... the UK, France , Italy ... to dilute the product only with dextrose solution.  ... 2015, the UK Court of Appeal held that Lilly,s patent ...
Breaking Medicine Technology: