Date:5/1/2012

Low dose whole body CT is nearly four times better than radiographic skeletal survey, the standard of care in the U.S., for determining the extent of disease in patients with multiple myeloma, a new study shows.

The study, conducted at the University of Maryland in Baltimore, included 51 patients who had both a radiographic skeletal survey as well as a low dose whole body CT examination. The total number of lesions detected in these patients with low dose whole body CT was 968 versus 248 detected by radiographic skeletal survey, said Kelechi Princewill, MD, the lead author of the study. "The stage of disease determines treatment, and the study found that in 31 patients, the stage of disease would have been different with low dose whole body CT. Thirteen patients would have been upstaged from stage I to stage II; nine patients would have been upstaged from stage I to stage III and nine patients would have been upstaged from stage II to III based on additional lesions detected on the low dose whole body CT," said Dr. Princewill.

Low dose whole body CT was significantly better than radiographic skeletal survey in detecting lesions in the spine, ribs, sternum and flat bones, added Dr. Princewill.

The use of low dose whole body CT is accepted in Europe as an accurate alternative to radiographic skeletal survey for detecting bone lesions in these patients, said Dr. Princewill. A concern about radiation dose may be one of the reasons why it is not widely accepted in the U.S., he said. "Our study employed a low dose protocol, with an average recorded CT dose of 4.1 mSv. That compares to 1.8 mSv for the radiographic skeletal survey. Using modified protocols and exposure parameters, we were able to significantly reduce the radiation doses to our patients without significantly compromising the image quality required to detect myeloma lesions. The average CT dose used in our study was approximately nine times lower than doses used in the acquisition of standard body CT studies," Dr. Princewill said.

The study is being presented on May 2 at the American Roentgen Ray Society annual meeting in Vancouver, Canada.


'/>"/>

Contact: Samantha Schmidt
sschmidt@arrs.org
703-858-4316
American Roentgen Ray Society
Source:Eurekalert

Related medicine news :

1. Low-Dose Aspirin to Prevent First Heart Attack or Stroke? Not So Fast
2. Low-Dose Aspirin After Lung Clot Could Prevent Recurrence
3. Even low-dose aspirin may increase risk of GI bleeding
4. Screening with low-dose spiral CT scanning reduces lung cancer deaths by 20 percent
5. New Blood Thinner Beats Plavix When Paired With Low-Dose Aspirin
6. Low-dose sorafenib may improve therapy for head and neck cancer
7. Low-dose chest CT effective in reducing radiation for evaluation of cardiothoracic surgery patients
8. Risk of cancer increases with exposure to low-dose radiation
9. Small bowel blood flow in healthy subjects receiving low-dose aspirin
10. Low-Dose Aspirin Boosts Accuracy of Colon Cancer Test
11. Low-dose aspirin reduces death rates from range of cancers by between 20 and 30 percent
Post Your Comments:
*Name:
*Comment:
*Email:
(Date:6/27/2016)... Park, KS (PRWEB) , ... June 27, 2016 , ... ... in retailers of Eyeglasses . , Millions of individuals in the United States ... eyeglasses have become a way to both correct vision and make a fashion statement. ...
(Date:6/26/2016)... ... June 26, 2016 , ... Pixel Film Studios Released ProSlice Levels, ... editors can give their videos a whole new perspective by using the title ... Pixel Film Studios. , ProSlice Levels contains over 30 Different presets to choose ...
(Date:6/26/2016)... (PRWEB) , ... June 26, 2016 , ... ... fertility once they have been diagnosed with endometriosis. These women need a treatment ... also require a comprehensive approach that can help for preservation of fertility and ...
(Date:6/25/2016)... ... ... closing of Bruton Memorial Library on June 21 due to a possible lice infestation, as ... of head lice: the parasite’s ability to live away from a human host, and to ... one in the event that lice have simply gotten out of control. , As lice ...
(Date:6/25/2016)... Beach, CA (PRWEB) , ... June 25, 2016 , ... ... UCLA with Magna Cum Laude and his M.D from the David Geffen School of ... Diego and returned to Los Angeles to complete his fellowship in hematology/oncology at the ...
Breaking Medicine News(10 mins):
(Date:6/23/2016)... DUBLIN , June 23, 2016 ... the "Surgical Procedure Volumes: Global Analysis (United States, ... Australia, Canada)" report to their offering. ... an essential tool for healthcare business planners, provides surgical ... looks at surgery trends with an in-depth analysis of ...
(Date:6/23/2016)... YORK , June 23, 2016 ... waters, but it continues to present great opportunities to ... companies for today: Intrexon Corp. (NYSE: XON ... Arena Pharmaceuticals Inc. (NASDAQ: ARNA ), and ... more about these stocks and receive your complimentary trade ...
(Date:6/23/2016)... DIEGO , June 23, 2016 ... programs that address medical conditions resulting from a ... it has appointed Greg Doyle as ... of Leading BioSciences, executive management team and board ... and chief financial officer. He will provide continued ...
Breaking Medicine Technology: