For automated purification of genomic and mitochondrial DNA from whole blood*

Format: 96-well plates (for 3296 samples in increments of 8) QIAamp DNA Blood MDX Protocol Sample sources: Fresh or frozen whole blood (with common anticoagulants such as citrate and EDTA) Sample volume: 200 l Preparation time: 2.5 hours (including load check of 20 minutes) Typical yield: 36 g per 200 l healthy whole blood Elution volume: 200 l The QIAamp DNA Blood BioRobot MDx Kit provides automated, high-throughput DNA purification on the BioRobot MDx using proven QIAamp technology. The fully automated procedure, including bar code reading and complete process documentation, requires less than 2.5 hours to process 96 samples (including a detailed load check of 20 minutes) with no hands-on time during the run. The resulting DNA performs well in downstream amplification and Southern blotting assays (see figures "No PCR Inhibition" and "Reliable Real-Time PCR"). Advantages of the system include high process reliability and walkaway automation, providing a highly efficient DNA purification system for clinical laboratories.

No PCR Inhibition



A 1.2 kb fragment of the single-copy Hugl gene was amplified from DNA purified with the QIAamp DNA Blood BioRobot MDx Kit, using HotStarTaq DNA Polymerase in a 50 l reaction volume. No inhibition was observed using either A 1 l of eluate or B 20 l of eluate as template. (Data generated by QIAGEN R&D.)

Reliable Real-Time PCR



The QIAamp DNA Blood BioRobot MDx Kit was used to purify genomic DNA from 96 whole blood samples (each 200 l) collected from a single donor. The -actin gene was amplified from the purified DNA using the TaqMan system. An amplification plot of 96 PCR reactions is shown. (Data generated by QIAGEN R&D.)

* QIAamp Kits are intended as general-purpose reagents. No claim or representation is intended for their use to identify any specific organism or for clinical use (diagnostic, prognostic, therapeutic, or blood banking). It is the users responsibility to validate the performance of QIAamp Kits for any particular use, since the performance characteristics of these kits have not been validated for any specific organism.
Wash buffers are labeled with bar codes and expiration date as stated on the Q-card in the kit.

'"/>

Source:


Page: All 1 2

Related biology technology :

1. Fast and Easy Isolation of PCR-Ready Genomic DNA from Whole Blood
2. Genomic DNA Extraction from Buccal Swabs Using the Perfect gDNA Blood Mini Kit
3. Genomic DNA Extraction from Buffy Coat Using the Perfect gDNA Blood Mini Kit
4. EppendorfPerfect gDNA Blood Mini Kit
5. Higher gDNA Concentrations with the Perfect gDNA Blood Mini Kit by Varying the Final Elution Volume
6. Isolation of Genomic DNA from Saliva Using the Perfect gDNA Blood Mini Kit
7. Genomic DNA Extraction from Buccal Swabs Using the Perfect gDNA Blood Mini Kit
8. Higher gDNA Concentrations with the Perfect gDNA Blood Mini Kit by Varying the Final Elution Volume
9. EppendorfPerfect gDNA Blood Mini Kit
10. Genomic DNA Extraction from Buffy Coat Using the Perfect gDNA Blood Mini Kit
11. Isolation of Genomic DNA from Saliva Using the Perfect gDNA Blood Mini Kit
Post Your Comments:
*Name:
*Comment:
*Email:


(Date:6/23/2016)... ... 2016 , ... Supplyframe, the Industry Network for electronics hardware ... . Located in Pasadena, Calif., the Design Lab’s mission is to bring together ... built and brought to market. , The Design Lab is Supplyframe’s physical representation ...
(Date:6/23/2016)... ... June 23, 2016 , ... In a new case report published ... how a patient who developed lymphedema after being treated for breast cancer benefitted from ... the paradigm for dealing with this debilitating, frequent side effect of cancer treatment. ...
(Date:6/23/2016)... Calif. , June 23, 2016  Blueprint Bio, ... biological discoveries to the medical community, has closed its ... Matthew Nunez . "We have received ... with the capital we need to meet our current ... essentially provide us the runway to complete validation on ...
(Date:6/23/2016)... , June 23, 2016 On ... session at 4,833.32, down 0.22%; the Dow Jones Industrial Average ... 500 closed at 2,085.45, down 0.17%. Stock-Callers.com has initiated coverage ... INFI ), Nektar Therapeutics (NASDAQ: NKTR ), Aralez ... Inc. (NASDAQ: BIND ). Learn more about these ...
Breaking Biology Technology:
(Date:6/9/2016)... innovation leader in attendance control systems is proud to announce the introduction of fingerprint ... sure the right employees are actually signing in, and to even control the opening ... ... ... Photo ...
(Date:6/3/2016)... June 3, 2016 ... Nepal hat ein ... hochsicherer geprägter Kennzeichen, einschließlich Personalisierung, Registrierung und ... der Produktion und Implementierung von Identitätsmanagementlösungen. Zahlreiche ... im Januar teilgenommen, aber Decatur wurde als ...
(Date:6/2/2016)... 2016 Perimeter Surveillance & Detection ... Physical Infrastructure, Support & Other Service  The ... offers comprehensive analysis of the global Border Security ... revenues of $17.98 billion in 2016. Now: ... leader in software and hardware technologies for advanced video ...
Breaking Biology News(10 mins):