The key to developing long-term instrument control applications is flexible and scalable software and hardware that enable seamless connectivity to any instrument in your application and offer built-in capabilities for advanced data analysis and presentation. Your choice of instrument should not limit or control your software choice, and your software preference should not limit the instrument that you pick for your application. The two decisions, the instrument and the software, should be independent of each other, empowering you to select the most optimal instrument and advantageous software environment for your application.

To attain flexible instrument control and connectivity, you need:

  • Seamless industry-standard software integration
  • Breadth of hardware connectivity options
  • Comprehensive instrument driver coverage

This white paper details industry-standard options available to deliver these benefits, helping you choose the right software and hardware solutions for your application. Table of Contents:
  • Key Characteristics of Instrument Control Software
  • Hardware Breadth
  • Instrument Driver Applicability
  • Instrument Drivers
  • Plug and Play
  • Interchangeable Virtual Instrument (IVI)
  • Direct I/O Connectivity
  • Conclusion

Key Characteristics of Instrument Control Software

There are several critical characteristics to look for as you evaluate a software tool to use for application development. Making the right decision about your application development environment (ADE) helps ensure your projects success by delivering the tools needed to develop higher quality products faster.

Key characteristics of instrument control software
1) Complete ADE versus a limited-functionality executable
2) Built-in instrument connectivity functions
3) Analysis and presentation capabilities

1) Complete ADE versus a limited functionality executable
A complete application development environment provides considerable advantages over a preprogrammed software tool. Complete ADEs deliver flexibility and power to you for customization, application integration, system connectivity and more. That flexibility combined with measuremen-and-automation-specific tools delivers the fundamentals of virtual instrumentation Virtual instrumentation represents a fundamental shift from traditional hardware-centered instrumentation systems and defined software packages to flexible, measurement-and-automation-software-centered systems that exploit the computing power, productivity, display, and connectivity capabilities of popular desktop computers and workstations. Although the PC and integrated circuit technology have experienced significant advances, it is software that truly provides the leverage to build on this powerful hardware foundation to create virtual instruments, providing better ways to innovate and significantly reduce cost. empowering engineers and scientists to build measurement and automation systems that suit their needs exactly (user-defined) instead of being limited by traditional fixed-function instruments and a software executable (vendor-defined) limited in functionality.

2) Built-in instrument connectivity functions
Another key to ensure project success is the out-of-the-box capabilities of the software package. To meet demanding project deadlines, you need software that does some of the work for you. Built-in instrument connectivity functions save you significant development time. There is a considerable difference between calling one native query command to communicate with your instrument and declaring the function through a DLLImport command, instructing the compiler to marshal the parameters, transferring control, throwing an exception to the managed caller, and then calling the query command.

3) Analysis and presentation capabilities
Finally, you should ensure that your software includes robust analysis and presentation capabilities. Once you have acquired the data from your instrument, you need built-in powerful algorithms and functions designed specifically for measurement analysis and signal processing. If the software package you choose does not contain measurement analysis functions, you are forced to write your own algorithms to turn raw data into critical information. With proper software capabilities, you can extract information from acquired data and unique measurements, generate, modify, process, and analyze signals, add intelligence and decision-making capabilities to your applications, perform inline and offline analysis, and then present information in a professional user interface designed for measurement data or to your data management sytems.

Lets look at how these three features are presented in the industry standard development environments: NI LabVIEW, NI LabWindows/CVI, and Microsoft Visual Studio.

LabVIEW
LabVIEW is a complete graphical development environment. It is a highly interactive and open environment for the rapid prototyping and incremental development of applications, from measurement and automation to real-time embedded to hardware design. LabVIEW delivers all of the flexible benefits of traditional development environments in addition to revolutionary, rapid development capabilities through graphical programming. With LabVIEW, you can design custom virtual instruments by creating a graphical user interface through which you:
Operate the instrumentation program
Control selected hardware
Analyze acquired data
Display results
You can customize front panels with knobs, buttons, dials, and graphs to emulate control panels of traditional instruments, create custom test panels, or visually represent the control and operation of processes. The similarity between standard flow charts and LabVIEW graphical programming shortens the learning curve associated with traditional, text-based languages.

Figure 1. LabVIEW graphical programming block diagram and user interface


You determine the behavior of the virtual instruments by connecting icons together to create block diagrams, which are natural design notations for scientists and engineers. With graphical programming, you can develop systems more rapidly than with conventional programming languages, while retaining the power and flexibility needed to create a variety of applications.

LabWindows/CVI
LabWindows/CVI is also a complete development environment, but one based on ANSI C as opposed to graphical development. In the same way that LabVIEW offers the flexibility delivered by a measurement and automation-specific environment, so does LabWindows/CVI. LabWindows/CVI streamlines ANSI C development with hardware configuration assistants, comprehensive debugging tools, and interactive execution to run functions at design time. Built-in measurement libraries enable rapid development of complex instrument applications including direct bus support, analysis functions, and user interface controls

Microsoft Visual Studio
Microsoft Visual Studio, including Visual C# .NET, Visual Basic .NET, Visual Basic 6.0, and Visual C++ is also a complete development environment. However, unlike LabVIEW and LabWindows/CVI, the Microsoft Visual Studio environment is a general-purpose tool not designed or optimized for measurement and automation application development. Therefore, it does not contain built-in tools for measurement and automation-specific tasks including instrument control, measurement data analysis or measurement data presentation. This is where NI Measurement Studio add-in tools help you. Measurement Studio takes the general-purpose Visual Studio environment and integrates native instrument control interfaces, advanced analysis routines, and native user interface controls specifically designed to display measurement data.

Once you have chosen the appropriate software environment you then need to determine the I/O bus and I/O connectivity that works best with for your measurement.

Hardware Breadth

There are several hardware options for communicating with and controlling your instruments. Historically, most users have controlled their instruments through mature buses, namely GPIB and Serial (RS-232). However some emerging commercial computer buses such as Ethernet and USB are appearing in the test and measurement arena. Combining existing instruments based on original communication buses such as GPIB and Serial with the latest instruments that rely on Ethernet and USB interfaces results in systems that are commonly referred to as Mixed I/O Test Systems. In order to effectively develop and maintain Mixed I/O Systems the software plays an important role. You need software tools that can support a wide variety of bus protocols in addition to scalable hardware solutions such as the options listed below.

General Purpose Interface Bus
The General Purpose Interface Bus (GPIB) has been one of the most common I/O interfaces present in instruments for many years. GPIB was designed specifically for instrument control applications. The IEEE 488 specifications which standardized this bus define the electrical, mechanical, and functional specifications of the bus while also defining its basic software communication rules. GPIB is a digital 8-bit parallel communications interface capable of achieving data transfers of up to 8 Mbytes/s, while supporting the connection of 14 instruments in addition to a system controller. GPIB provides robust shielded connectors that are designed for rugged industrial environments.
NI GPIB hardware comes complete with the NI-488.2 driver which includes native interfaces for LabVIEW, LabWindows/CVI, Visual Basic 6.0, Visual Basic .NET, Visual C# .NET, and Visual C++. In addition, you can also communicate with GPIB hardware through the Virtual Instrumentation Software Architecture (VISA) VISA is a standard architecture originally defined by the VXI plug&play Systems Alliance, founded in 1993, to provide a common foundation for the development, delivery, and interoperability of high-level, multivendor software system components including support for GPIB, VXI, PXI, VME, Serial and/or USB interface.. VISA offers native interfaces for LabVIEW, LabWindows/CVI, Visual Basic 6.0, Visual Basic .NET, Visual C# .NET, and Visual C++.

Serial (RS-232)
RS-232 is a specification for serial communication and is popular in analytical and scientific instruments. It is also commonly used to control modems and printers. Unlike GPIB, with the RS-232 interface you can connect and control only one device at a time. RS-232 is also a relatively slow interface, with typical data rates of less than 20kbytes/s.
NI serial hardware is packaged with the NI-Serial driver. You access the NI-Serial driver though the Windows Serial API or the NI-VISA API with native interfaces for LabVIEW, LabWindows/CVI, Visual Basic 6.0, Visual Basic .NET, Visual C# .NET, and Visual C++.

Ethernet
Recently, instrument vendors have begun to include Ethernet as an alternative communication interface on stand-alone instruments. Although new to instrument control applications, Ethernet is a mature technology that is widely used for measurement systems albeit in other capacities. Advantages of Ethernet for instrument control applications include remote control of instruments, sharing among different users at different locations, and easier data integration and publication. Most common Ethernet networks today can transfer data at 10 Mb/s, 100 Mb/s, or even 1 Gb/s with the new Gigabit Ethernet standard. However, these are theoretical maximum transfer rates and applications most likely will not achieve the same performance. In addition, data transfers across Ethernet are not deterministic and extra security measures, such as firewalls, should be taken to ensure data integrity.
You can control and communicate with Ethernet instruments through the VISA interface natively in LabVIEW, LabWindows/CVI, Visual Basic 6.0, Visual Basic .NET, Visual C# .NET, and Visual C++.

USB
The Universal Serial Bus (USB) was designed primarily to connect peripheral devices, such as keyboards and mice, to PCs. The USB is a plug & play bus, supports up to 127 devices on one port, and has a theoretical maximum throughput of 480 Mb/s (high-speed USB defined by the USB 2.0 specification). Since USB ports come standard on today's PCs, USB is viewed as a natural evolution of conventional serial port technology. Some of the bus features may prevent it from achieving widespread appeal. These include the fact that cables are not industrially graded, are sensitive to noise, and can accidentally become detached, and the maximum distance between the controller and the device is 30m.
You can control and communicate with Ethernet instruments through the VISA interface natively in LabVIEW, LabWindows/CVI, Visual Basic 6.0, Visual Basic .NET, Visual C# .NET, and Visual C++.

FireWire
FireWire, or IEEE 1394, is a high-performance serial bus originally developed by Apple computer in the early 1990s. The baseline standard handles throughput rates of up to 400 Mbits/s. The IEEE 1394 Trade Association is revising the specification to increase this transfer rate to 3.2 Gbits/s. While devices must be within 4.5m of the bus socket to conform to the specification, up to 16 devices can be daisy-chained together for a maximum run of 72 m. IEEE 1394 however, is less than ideal for T&M applications. For example, the 1394 cables are not industrial graded, the isochronous mode allows this bus to guarantee bandwidth but does not guarantee that no data will be lost, andapplication testing shows 1394 data transfers to be much lower than their theoretical values.
You can control and communicate with 1394-based instruments through the drivers that ship with the device as a DLL interface to your software development environment including LabVIEW and LabWindows/CVI.

Wireless
Wireless Ethernet (IEEE 802.11) is another emerging standard for I/O buses that can be leveraged in instrument control applications. While it is capable of slower transfer rates than standard Ethernet and suffers from some of the same security issues, it offers the convenience of remote control without the necessity for cabling. Another potential wireless bus alternative that is not discussed here is Bluetooth.
You can control and communicate with IEEE 802.11 instruments through the drivers that ship with the device as a DLL interface to your software development environment including LabVIEW and LabWindows/CVI.

Bus Bridges
Although these buses may offer some advantages for instrument communication, they do have some of the drawbacks mentioned above and there is no clear choice of which bus, if any, will gain the widespread acceptance of GPIB. As a result, instrument manufacturers have been slow to make these buses available on their products. A viable alternative to native bus communication is through bus bridge products available on the market. These bridges allow you to convert from one bus type to another (e.g., convert from USB or Ethernet to GPIB or Serial).

Bus converters offer some great advantages for instrument control. They allow you to take advantage of some of the advanced capabilities of these new buses on your computer, while maintaining your investment in your programs. Good bridges should be software transparent allowing you to use, unchanged, applications written for plug-in boards of the same bus (i.e., a USB to GPIB converter and plug-in GPIB board).
You can control and communicate with bus bridges either through the NI-VISA API or the NI-488.2 interface natively in LabVIEW, LabWindows/CVI, Visual Basic 6.0, Visual Basic .NET, Visual C# .NET, and Visual C++.

Bus I/O Software
Bus bridges help the user ease their way into using new bus technology. However, the future holds the promise of test systems that integrate mature buses, some of the newer buses discussed earlier, as well as others that may come into play in the future. The key to integrating all of these buses seamlessly into one system is through the use of good software architectures and powerful software environments.

See Also:
NI-GPIB
Instrument Control

Instrument Driver Applicability

There are several different ways to control your instruments - you can either use an instrument driver or control the instrument through direct I/O commands (See Figure 2).

Figure 2 - Instrument drivers and interactive, direct I/O tools for instrument control

In general, NI recommends the use of an instrument driver if one is available because of the clear time-saving benefits. NI recognized early the importance of instrument drivers and in 1990 created the now industry leading instrument driver repository - The Instrument Driver Network ( ni.com/idnet ). This on-line resource currently provides more than 2,200 instrument drivers from over 150 different instrument vendors.
An instrument driver is a VI, library, or class that contains high-level functions that allow you to control a specific instrument or family of instruments. If you cannot find an instrument driver for your particular instrument or if you do not need to use an instrument driver, NI software offers several interactive tools to facilitate direct I/O control and communication as well.
Some reasons why you would not use an instrument driver include:
You only need to send a few commands to your instrument
An instrument driver does not exist
You do not need to distribute a set of instrument commands to other developers

See Also:
Instrument Driver Network

Instrument Drivers


Instrument drivers are the key to rapid development of test and measurement applications. By providing high-level and modular VIs, libraries, and classes for easy programming, they eliminate the need for you to learn complex programming protocols. An instrument driver is a set of software routines that correspond to a programmatic operation such as configuring, reading from, writing to, and triggering the instrument.

National Instruments provides instrument drivers for a wide variety of instruments; these instrument drivers are written in LabVIEW and/or LabWindows/CVI and use the Virtual Instrumentation Software Architecture (VISA) API for instrument control.

Figure 3 A variety of instrument drivers provide different levels of functionality and complexity.

Plug and Play

Plug&Play Instrument Drivers simplify controlling and communicating with your instrument through a standard and simple programming model for all drivers. Plug&Play Instrument Drivers provide native source code for LabVIEW and LabWindows/CVI.

LabVIEW Plug&Play Drivers

A LabVIEW Plug&Play instrument driver is a set of VIs used to control and communicate with a programmable instrument. Each VI corresponds to a programmatic operation such as configuring, reading from, writing to, and triggering the instrument. LabVIEW Plug&Play instrument drivers comply with requirements and recommendations for programming style, error handling, front panels, block diagrams, icons, and online help. Because LabVIEW Plug&Play drivers maintain a common architecture and interface, you quickly and easily connect to and communicate with your instruments with very little or no code development. Moreover, with the standard programming model of LabVIEW Plug&Play instrument drivers, you can easily add instruments to your test system without worrying about learning new communication protocols or spending time understanding new programming paradigms.

In addition, LabVIEW instrument drivers that meet National Instruments requirements and recommendations do not rely on constantly changing technology such as Microsoft technologies. Instead, these instrument drivers are long-term solutions delivering more than a decade of compatibility. With LabVIEW instrument drivers, you can use an instrument driver written in 1992 in your test application today with little or no code modification.

LabWindows/CVI Plug&Play Drivers

A LabWindows/CVI Plug&Play instrument driver is a set of ANSI C software routines used to control and communicate with a programmable instrument. Each routine corresponds to a programmatic operation such as configuring, reading from, writing to, and triggering the instrument. LabWindows/CVI Plug&Play instrument drivers comply with requirements and recommendations for programming style, error handling, function panels, function trees, and help files. Because LabWindows/CVI Plug&Play drivers maintain a common architecture and interface, you quickly and easily connect to and communicate with your instruments with very little code development. Moreover, with the standard programming model of LabWindows/CVI Plug&Play instrument drivers, you can easily add instruments to your test system without worrying about learning new communication protocols or spending time understanding new programming paradigms. As with LabVIEW, LabWindows/CVI Plug&Play instrument drivers deliver long-term compatibility.

Interchangeable Virtual Instrument (IVI)


Interchangeable Virtual Instruments (IVI) Drivers are more sophisticated instrument drivers that feature increased performance and flexibility for more complex test applications that require interchangeability, state-caching, or simulation of instruments. IVI drivers are based on industry standards developed by the IVI Foundation The Interchangeable Virtual Instruments (IVI) Foundation was founded to create an instrument driver standard that builds on the VXI plug&play standards but also provides features such as instrument interchangeability, simulation, state-caching, and multithread safety. The IVI Foundation is comprised of user companies such as Boeing, integrators such as BAE Systems, and instrument and software vendors such as National Instruments, Agilent Technologies, and Tektronix. The IVI Foundation was founded in 1998, incorporated in March of 2001, and has an active membership of 27 companies.. IVI driver capabilities include state-caching and multithreading to deliver higher performance, simulation to increase productivity, and instrument interchangeability to maximize software reuse across similar instrument types.

National Instruments IVI drivers deliver a dramatic performance improvement by integrating a state-caching engine that only sends commands to the instrument necessary to incrementally change its state.

The IVI Foundation defines two architectures for IVI drivers, one based on ANSI-C and the other on Microsoft Component Object Model (COM) technology. Both architectures are designed to coexist and are not mutually exclusive. IVI-C drivers and IVI-COM drivers can be used in the same application.

Although the technologies underlying IVI-C and IVI-COM are different, the implementation technology by itself should not be your primary concern. Instead, focus on two key issues: 1) the longevity of the architecture on which the instrument driver is based, and 2) the usability of instrument drivers in your ADE.

Architectural Longevity
The issue of architectural longevity is particularly important to users of IVI drivers. Interchangeability is one of the most beneficial features of IVI, and a primary reason for achieving interchangeability is to make it easier to replace instruments in systems that must last 10 to 20 years. Having a common API for instrument drivers is not sufficient if the architecture on which those instrument drivers are based changes every few years.

For this reason, National Instrument prefers to adhere to the IVI-C architecture. ANSI-C is a long established standard that is available on all platforms, and is expected to remain so. Conversely, COM is not available on all platforms and has already been superseded by .NET which was introduced by Microsoft in 2002.

Usability
One of the key motivations behind IVI-COM drivers is the desire to develop one driver that works automatically in all development environments. Unfortunately, this comes at the expense of usability. IVI-COM drivers present an interface style that is optimal only in Microsoft Visual Basic 6.0, which was superseded by Microsoft Visual Basic .NET.

Ideally, instrument drivers should present an optimal interface for each development environment in which they are used. For example, instrument drivers should be presented as a set of LabVIEW VIs for use in LabVIEW, a set of C++ classes for use in Microsoft Visual C++, and a set of .NET classes for use in Microsoft Visual Basic.NET and Visual C#.

National Instruments follows this model in implementing IVI drivers. Our focus is on providing native support for NI development environments, LabVIEW and LabWindows/CVI. We also provide support for other environments as they become popular. Our IVI-C drivers ship with ANSI-C interfaces, LabWindows/CVI function panels, and LabVIEW VI wrappers. For message based devices, we include the ANSI-C source code with the driver. We also provide C++ wrappers for IVI drivers for our Measurement Studio users. In the future, we also intend to provide .NET assembly wrappers for our IVI drivers. As Visual Basic 6.0 becomes obsolete through the growing Visual Basic .NET adoption, National Instruments does not plan to develop COM wrappers for our IVI-C drivers.

If you need interchangeability and simulation in your test applications, IVI drivers provide a robust tool to save you significant development time and maintenance costs.

To build an interchangeable test system that can stand the test of time, IVI-C drivers are the best choice. However, if all that is available for your instrument is an IVI-COM or VXI plug&play instrument driver, then you should use it. Your goal is to be able to easily communicate with your instruments and not to be tied to one driver technology or another.

See Also:
How IVI-C Instrument Driver Technology Enables System Longevity and Platform Portability

Direct I/O Connectivity

If there is not an instrument driver available; you should take advantage of the interactive, direct I/O capabilities built into the software development environments. NI software offers the Instrument I/O Assistant, built-in VISA and bus-specific interfaces, and several debugging tools within Measurement and Automation Explorer (not covered in this document) including NI Spy, Interface Bus Interactive Control (IBIC for GPIB), and VISA Interactive Control (VISAIC).

Instrument I/O Assistant
Instrument I/O Assistant provides a user interface to interactively write commands to a device, read data that the device returns, and specify how to parse the response into a format relevant to your application. It is fully integrated into LabVIEW, LabWindows/CVI, Visual Studio .NET through Measurement Studio, and Visual C++ through Measurement Studio. Instrument I/O Assistant simplifies the challenge of writing instrumentation applications by automatically generating code from your configurations in your environment.

Figure 4 - Interactive Instrument I/O Assistant Dialog

The Instrument I/O Assistant also helps you quickly parse complex responses from an instrument for use in native-code instrument drivers. Because string parsing can be complex, using the assistants interactive window to parse complicated responses can save you time in creating your instrument application.

Built-in Instrument Control and Connectivity Functions
Having built-in support for direct instrument control and connectivity will save you countless hours of low-level development time. Built-in LabVIEW, LabWindows/CVI, and Measurement Studio for Visual Basic 6.0, Visual Basic .NET, Visual C# .NET, and Visual C++ support is provided through native libraries or NI-VISA for GPIB, PXI, Serial, Ethernet, USB, and more.

See Also:
LabVIEW Instrument Control Demo
Measurement Studio for Visual Studio .NET White Paper
LabWindows/CVI White Paper

Conclusion

The key to developing long-lasting instrument control applications is flexible and scalable software and hardware that enable seamless connectivity to any instrument in your application as well as built-in capabilities for advanced data analysis and presentation.

NI delivers the most flexible instrument control and connectivity tools by providing:

  • Optimized industry-standard software development environments and add-ins,
  • Breadth of hardware connectivity options,
  • Long-term compatibility, and
  • Comprehensive instrument driver coverage,
empowering you to choose the most optimal instrument and advantageous software for your instrument control applications.
See Also:
Instrument Driver Network

'"/>

Source:


Page: All 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Related biology technology :

1. Drive Long-Term Silencing with CMV Vectors
2. QIAGEN Instrument Service insist on the best in service and support
3. QIAGEN Instrument Service - insist on the best in service and support
4. Integration of the LEADseeker Multimodality Imaging System with automated plate loading and incubation using Overlord Instrument software
5. National Instruments DIAdem -- Complete Your Technical Data Management Framework with Powerful Off-line Analysis, Visualization, and Report Generation
6. Control RT-PCR Primers for Human Gene Transcripts with Varying Abundance
7. Versatile Vectors for Ponasterone A- Inducible Control of Gene Expression in Mammalian Cells
8. Human t-PA Control Primer Set
9. Rapid PCR* Using Active Tube Temperature Control On Thermos PCR Machines
10. Housekeeping Genes: Universal Positive Controls in siRNA Knockdown Experiments
11. Control Your siRNA Research
Post Your Comments:
*Name:
*Comment:
*Email:
TAG: Long Term Instrument Control and Connectivity Solutions

(Date:9/19/2014)... 18, 2014 Scientists at NYU Langone Medical Center ... efficiency of the process for turning adult cells into ... including vitamin C. Using the new technique in mice, ... from adult skin cells by more than 20-fold compared ... efficient and reliable, and thus should generally accelerate research ...
(Date:9/19/2014)...  Nektar Therapeutics (NASDAQ: NKTR ) ... analgesic profiles of a series of the company,s ... The preclinical research candidates were created using Nektar,s ... The analgesic properties of kappa receptor agonism are ... Kappa opioid receptors are expressed in the peripheral ...
(Date:9/19/2014)... 19, 2014 ... ) has announced the addition of the  "Micro ... to their offering.       (Logo: http://photos.prnewswire.com/prnh/20130307/600769) ... of the fastest-growing segments in the chromatography market. ... 2013, and expected to reach $2.0 billion by ...
(Date:9/18/2014)... About POCT POCT, ... clinical laboratory. It helps in making fast clinical ... medication. POCT is gaining popularity due to the ... as diabetes, heart disease, and obesity. It is ... to minimize errors during the diagnosis of patients. ...
Breaking Biology Technology:NYU Langone scientists report reliable and highly efficient method for making stem cells 2NYU Langone scientists report reliable and highly efficient method for making stem cells 3Nektar Presents Positive Preclinical Data on Oral, Peripherally-Acting Kappa Agonist Molecules at 2014 American Academy of Pain Management Meeting 2Nektar Presents Positive Preclinical Data on Oral, Peripherally-Acting Kappa Agonist Molecules at 2014 American Academy of Pain Management Meeting 3Nektar Presents Positive Preclinical Data on Oral, Peripherally-Acting Kappa Agonist Molecules at 2014 American Academy of Pain Management Meeting 4Nektar Presents Positive Preclinical Data on Oral, Peripherally-Acting Kappa Agonist Molecules at 2014 American Academy of Pain Management Meeting 5Micro Market Monitor : Global Pre-packed Chromatography Columns 2POCT Market in China 2014-2018 2
... Insmed Incorporated (Nasdaq CM: INSM), a biopharmaceutical company, announced ... will be presenting a corporate overview at the 2011 ... August 16, 2011, at 8:00 AM ET, in New ... available on the Investors page of Insmed,s website, ...
... and BERGEN, Norway, August 11, 2011 Valkee ... and scientists from the University of Oulu will present new ... Annual Meeting 2011, August 12-14. Their research localized ... - in all of the 18 evaluated areas of the ...
... 10, 2011 Exagen Diagnostics, Inc. , a ... markets proprietary tests for rheumatologists and gastroenterologists, announced today ... Operating Officer. Tornoe has more than 20 ... and marketing, making him a key hire as Exagen ...
Cached Biology Technology:Insmed to Present at 2011 Wedbush Securities Life Sciences Management Access Conference 2The Human Brain is Sensitive to Light, Breakthrough Findings From Valkee and the University of Oulu 2The Human Brain is Sensitive to Light, Breakthrough Findings From Valkee and the University of Oulu 3Eric Tornoe Joins Exagen Diagnostics as President and COO 2
(Date:9/18/2014)... colleagues have built the first smartphone app that ... behavioral trends. In other words, your smartphone knows ... don,t -- and how that affects you. , ... depression and loneliness to their academic performance, also ... for example, to monitor mental health, trigger intervention ...
(Date:9/18/2014)... so you might expect that most would have an ... dogs are distinctly more pessimistic than others, research from ... is exciting because it measures positive and negative emotional ... and dog owners an insight into the outlook of ... from the Faculty of Veterinary Science. Her PhD research ...
(Date:9/18/2014)... The global cycles of carbon and nitrogen comprise ... human and environmental systems have caused imbalances and ... greenhouse gases (GHGs). Increased GHGs result in climate ... terrestrial ecosystems, oceans and the atmosphere. Understanding these ... exciting branch of environmental science during the past ...
Breaking Biology News(10 mins):New Dartmouth smartphone app reveals users' mental health, performance, behavior 2New Dartmouth smartphone app reveals users' mental health, performance, behavior 3New Dartmouth smartphone app reveals users' mental health, performance, behavior 4Dogs can be pessimists too 2Dogs can be pessimists too 3Greenhouse gas research enters a new era 2
... cellsas indicated by a molecular imaging techniquecould tell researchers ... headaches and psychosis in schizophrenic patients, occur and provide ... two studies published in the November issue of the ... positron emission tomography (PET)a noninvasive molecular imaging techniqueresearchers were ...
... When 100 m sprinters launches themselves from the starting blocks, ... few strides. Acceleration through the first few strides is the ... by an American football star, who sprints in his position ... his technique and training regime, Piazza decided to focus on ...
... have confirmed that the largest bat in Europe, ... the Late Pleistocene (between 120,000 and 10,000 years ago). ... at Abrc Roman (Barcelona) prove that this bat had ... than it does today, having declined due to the ...
Cached Biology News:Unlocking mysteries of the brain with PET 2Short heels make elite sprinters super speedy 2The largest bat in Europe inhabited northeastern Spain more than 10,000 years ago 2
... kit for stabilizing 400g of purified RNA ... for the stabilization of aqueous RNA samples ... such as guanidine, phenol/chloroform, silica, oligo dT ... Kits contain all the necessary components for ...
...
... wide mouth PYREX Fernbach-style culture flasks have ... the flask bottom to achieve maximal oxygen ... flasks have a Delong-style 38mm neck for ... For plastic closures see Nos. CLS2679638 or ...
... Fernbach-style culture flask is designed for culturing organisms ... It can also be used in serum production. ... achieve maximal oxygen transfer to culture medium. Beaded ... cotton plugs or No. 13 rubber stoppers. This ...
Biology Products: