MessageAmp II-96 aRNA Amplification Kit


Amplify as little as 100 ng of input RNA in a single round for GeneChip analysis

Includes ArrayScript, an engineered M-MLV RT, to maximize yields of full-length cDNA

aRNA synthesis powered by MEGAscript High Yield Transcription Kit, the best technology for in vitro transcription

High labeling efficiency yields consistently high percent present calls and low 3'/5' ratios in GeneChip analysis


MessageAmp II-96 aRNA Amplification Kit is the first kit designed for high throughput amplification of mRNA and is based on the patented Van Gelder-Eberwine linear RNA amplification method. This kit takes advantage of extensive improvements incorporated into the MessageAmp II aRNA Kit combined with a new magnetic bead-based purification of both the cDNA and the aRNA.

The new microplate format available with MessageAmp II-96 provides a simple, streamlined procedure for the entire aRNA amplification process, including first and second strand cDNA synthesis, in vitro transcription, and aRNA labeling. Figure 1 illustrates aRNA yields obtained with either the manual or the fully-automated MessageAmp II-96 protocol at various HeLa total RNA input levels for both 4 and 14 hour IVT reactions. Figure 2 compares the correlation coefficients (% present calls on Affymetrix Human Genome Focus Arrays) obtained using MessageAmp II-96 (Plate 1 and Plate 2) versus Ambion's st andard single-tube MessageAmp II reaction.


[click here to enlarge]

Figure 1. Robotic or Manual RNA Amplification using MessageAmpII-96 aRNA Amplification Kit. Twelve replicates of HeLa cell total RNA inputs (5, 1, 0.3, and 0.1 g) were processed according to the MessageAmp II-96 protocol either on the Biomek 2000 (Robot, Beckman-Coulter) or manually (human). In vitro transcription (IVT) times of (A) 14 hours and (B) 4 hours were used. Following aRNA clean-up, yield was assessed by measuring UV absorbance at 260 nm.


[click here to enlarge]

Figure 2. Correlation Coefficients of aRNA Data Obtained with MessageAmp II-96 Kit. HeLa cell total RNA (Control RNA included in MessageAmp II-96 aRNA Amplification Kit) was used to prepare biotin-labeled aRNA following the standard MessageAmp II-96 protocol (Plate-1 and Plate-2) and MessageAmp II protocol (tube). aRNA (10 g) was analyzed on an Affymetrix Human Genome Focus Array, and the correlation coefficients were calculated for the percent present calls.


Magnetic beads are used for both the cDNA and aRNA purification steps, eliminating the need for vacuum filtration or centrifugation. The use of beads also enables elution into smaller volumes, thus providing a higher concentration of aRNA. The entire process can be performed either manually or fully automated using a robot integrated with a thermal cycler and orbital shaker. Each kit contains sufficient reagents to amplify 100 samples, thus providing four samples for pre-testing prior to using a 96 well format.


Scientific Contributors

Chris Willis, Sharmili Moturi, Xingwang Fang Ambion, Inc.


back to top


Ordering Information
Cat# Product Name Size 1819 MessageAmp II-96 aRNA Amplification Kit 100 rxns 10027 Magnetic Stand-96 1 each 10050 96 well Magnetic-Ring Stand 1 each
'"/>

Source:


Page: All 1 2 3

Related biology technology :

1. Innovative Tissue Array Technology for High-Throughput Screening of Gene Expression
2. Highest Possible Transformation Efficiencies for High-Throughput Applications
3. High-Throughput Cultivation of Bacterial Clones
4. High-Throughput Isolation of Total RNA
5. High-Throughput System Generates Ultra-Pure PCR Products Suitable for All Applications
6. The DIG System Nonradioactive Automated High-Throughput In Situ Hybridization: a Powerful Tool for Functional Genomics Research
7. High Throughput siRNA Electroporation
8. High Throughput siRNA Delivery In Vitro: From Cell Lines to Primary Cells
9. High Throughput RNA Isolation for High Performance Microarray Analysis
10. RNAi for High Throughput Analysis
11. Robust High Throughput RNA Isolation from Blood Samples
Post Your Comments:
*Name:
*Comment:
*Email:


(Date:10/11/2017)... ROTTERDAM, the Netherlands and LAGUNA HILLS, ... that The Institute of Cancer Research, London ... will use MMprofilerâ„¢ with SKY92, SkylineDx,s prognostic tool to risk-stratify ... high-risk trial known as MUK nine . The University ... this trial, which is partly funded by Myeloma UK, and ...
(Date:10/10/2017)... ... October 10, 2017 , ... San Diego-based team building and ... rebranding initiative announced today. The bold new look is part of a transformation ... moves into a significant growth period. , It will also expand its service offering ...
(Date:10/10/2017)... Parks Associates announced today that Tom Kerber , Director ... , October 11 in Scottsdale, Arizona . Kerber will ... safety and security products impact the competitive landscape. ... Parks Associates: Smart Home Devices: Main Purchase Driver ... "The residential security market has experienced continued growth, and the introduction of ...
(Date:10/9/2017)... 2017  BioTech Holdings announced today identification and ... ProCell stem cell therapy prevents limb loss in ... demonstrated that treatment with ProCell resulted in more ... compared to standard bone marrow stem cell administration.  ... reduction of therapeutic effect.  ...
Breaking Biology Technology:
(Date:5/16/2017)... , May 16, 2017   Bridge Patient ... organizations, and MD EMR Systems , an ... partner for GE, have established a partnership to ... product and the GE Centricityâ„¢ products, including Centricity ... These new integrations will allow ...
(Date:4/17/2017)... , April 17, 2017 NXT-ID, Inc. (NASDAQ: ... announces the filing of its 2016 Annual Report on Form 10-K ... Commission. ... 10-K is available in the Investor Relations section of the Company,s ... the SEC,s website at http://www.sec.gov . 2016 Year ...
(Date:4/11/2017)... No two people are believed to ... York University Tandon School of Engineering and Michigan ... partial similarities between prints are common enough that ... and other electronic devices can be more vulnerable ... in the fact that fingerprint-based authentication systems feature ...
Breaking Biology News(10 mins):