Navigation Links
AMPURE PURIFICATION SYSTEM

AMPure is a high recovery, SPRI-based PCR clean up system capable of purifying amplicons as small as 100bp. AMPure yields high quality PCR amplicons using a simple, three-step protocol requiring no centrifugation or filtration steps. The protocol can be easily automated or performed manually in both 96 and 384-well formats.

EFFICIENT PCR PURIFICATION
AMPure provides:

  • Efficient removal of unincorporated dNTPs, primers and salts
  • High recovery of small and large amplicons
  • High quality PCR amplicons


  • FLEXIBLE PURIFICATION
    AMPure is flexible enough to be performed in a variety of formats for an array of applications:
    PLATFORMS: APPLICATIONS:
  • 96-well
  • PCR Sequencing
  • 384-well
  • cDNA labeling
  • Fully automated
  • Rolling Circle Amplification
  • Manual





    EFFECTIVE CLEAN UP
    AMPure removes unincorporated primers, dNTPs and salts used during PCR amplification. These products can interfere with downstream applications. AMPure routinely has recovery rates greater than 90% for amplicons larger than 200bp and greater than 85% for smaller PCR amplicons, such as the 165bp fragment shown in Figure 2. HIGH PURITY HIGH PERFORMANCE
    AMPure-purified samples are ideal sequencing templates. The table below shows sequencing results from a single 976bp PCR template purified using AMPure or ExoSAP-IT. The average Phred20 read length and average pass rate for the AMPure-purified samples were 701 and 100% respectively. ExoSAP-IT, an alternative approach of inactivating polymerases and degrading unincorporated primers following PCR thermo-cycling, produces samples with lower purity due to the presence of salts and degraded enzymes and primers. Sequence results following ExoSAP-IT digestions are consistently inferior, with fewer Phred20 bases per read and lower pass rates. Figure 3 exhibits the superior sequencing performance attained using AMPure. RELIABLE RESULTS
    AMPure produces reliable recoveries of both large and small amplicons. Figure 4 shows two gels following AMPure purification of 967 bp and 165 bp PCR fragments. SUPERIOR PERFORMANCE
    AMPure demonstrates excellent recovery rates of both small and large amplicons while maintaining high sample purity. AMPure samples have little to no contamination as shown by the lack of smearing above the bands (Figure 5). In contrast, alternative purification products have decreased recovery rates and/or lower sample purity, which affect the performance of downstream applications such as sequencing.
    COMPLETE AMPURE AUTOMATION
    The lack of centrifugation and filtration steps allows AMPure protocols to be completely automated while maintaining superior performance. AMPure is fully compatible with most commonly used low, medium and high throughout liquid handling systems. Contact Agencourt for the most up-to-date list of supported platforms.

    AMPure has been successfully automated on the Biomek FX from Beckman Coulter in 96 and 384-well formats. (Photo courtesy of Beckman Coulter.)



    '"/>


  • Source:


    Page: All 1 2 3

    Related biology technology :

    1. COSMCPREP HIGH AND LOW COPY PLASMID PURIFICATION
    2. SPRINTPREP SINGLE STEP PLASMID PURIFICATION
    Post Your Comments:
    *Name:
    *Comment:
    *Email:


    (Date:10/11/2017)... ... October 11, 2017 , ... The ... endogenous context, enabling overexpression experiments and avoiding the use of exogenous expression plasmids. ... is transformative for performing systematic gain-of-function studies. , This complement to loss-of-function ...
    (Date:10/11/2017)... LAGUNA HILLS, Calif. , Oct. 11, 2017  SkylineDx ... London (ICR) and University of Leeds ... to risk-stratify patients with multiple myeloma (MM), in a multi-centric ... The University of Leeds is the ... UK, and ICR will perform the testing services to include ...
    (Date:10/10/2017)... Angeles, CA (PRWEB) , ... ... ... Inc., a development-stage cancer-focused pharmaceutical company advancing targeted antibody-drug conjugate (ADC) therapeutics, ... uses of targeted HPLN (Hybrid Polymerized Liposomal Nanoparticle), a technology developed in ...
    (Date:10/10/2017)... BARBARA, CALIFORNIA (PRWEB) , ... October 10, 2017 ... ... management, technological innovation and business process optimization firm for the life sciences and ... BoxWorks conference in San Francisco. , The presentation, “Automating GxP Validation ...
    Breaking Biology Technology:
    (Date:7/20/2017)... (NYSE: DAL ) customers now can use fingerprints instead of ... Airport (DCA). ... Delta launches biometrics to board aircraft at Reagan Washington National Airport ... Delta,s biometric boarding pass experience that launched in May ... boarding process to allow eligible Delta SkyMiles Members who are enrolled in ...
    (Date:6/14/2017)... June 15, 2017  IBM (NYSE: IBM ) is introducing ... event dedicated to developing collaboration between startups and global businesses, ... 15-17. During the event, nine startups will showcase the solutions ... various industries. France ... market, with a 30 percent increase in the number of ...
    (Date:5/16/2017)... , May 16, 2017   Bridge ... health organizations, and MD EMR Systems , ... development partner for GE, have established a partnership ... Portal product and the GE Centricity™ products, including ... EMR. These new integrations will ...
    Breaking Biology News(10 mins):