Navigation Links
Rapid-Screen Arrayed cDNA Library Panels Master Plates -Rat Brain (adult) from OriGene Technologies

ProductsRapid-Screen Arrayed cDNA Library Panels Master Plates -Rat Brain (adult) from OriGene Technologies
Company OriGene Technologies
Item Rapid-Screen Arrayed cDNA Library Panels Master Plates -Rat Brain (adult)
Price $925.00
Description The Rapid-Screen cDNA Library Panels were designed for full-length gene cloning and require just three sets of PCRs to identify the desired cDNA clone. The first PCR analysis is performed in a 96-well "Master Plate," where each well contains plasmid DNA from 5,000 clones. Having identified the positive well(s) by gel electrophoresis of the reaction products, the second PCR analysis is carried out in the corresponding 96-well "Sub-Plate(s)," which contains all 5,000 clones from the positive well of the Master Plate arrayed at only 50 clones per well. Since this plate contains glycerol stocks of E. coli instead of plasmid DNA, the cells can be diluted and plated out once a positive well(s) has been identified. Analysis of 96 single colonies by PCR leads to the identification of the positive clone from the Sub-Plate well. To ensure that a clone detected in a specific well in the Master Plate will be represented in the appropriate Sub-Plate, the Sub- Plates were not derived by dilution of individual wells from the Master Plate (a process which may lose specific clones). Instead, the Sub-Plates were generated first and the wells from each Sub-Plate were then pooled to generate the Master Plate. To guarantee that clones from different wells in the Master Plate were each independently-derived, the Sub-Plates were generated with primary transformants that had not been amplified.
Info OriGene TechnologiesOriGene Technologies
6 Taft Court, Suite 100
Rockville, MD 20850
USA

Call OriGene Technologies to buy products (US and Canada only; other locations use numbers below)
USA Canada 1-866-592-4179
Customer Service: 1-888-267-4436 (U.S. only) / 301-340-3188
Fax Number: 301-340-9254
Web Site: http://www.origene.com
NOTE: Price information is approximate list price and actual prices may vary.

Related biology products :

1. Rapid-Screen Arrayed cDNA Library Panels Master Plates -Human Placenta from OriGene Technologies
2. Rapid-Screen Arrayed cDNA Library Panels Master Plates -Human Heart from OriGene Technologies
3. Rapid-Screen Arrayed cDNA Library Panels Master Plates -Mouse Testis from OriGene Technologies
4. Rapid-Screen Arrayed cDNA Library Panels Master Plates -Mouse Brain (adult) from OriGene Technologies
5. Rapid-Screen Arrayed cDNA Library Panels Master Plates -Mouse Embryo (12.5 - day) from OriGene Technologies
6. Rapid-Screen Arrayed cDNA Library Panels Master Plates -Mouse Embryo (19 - day) from OriGene Technologies
7. Rapid-Screen Arrayed cDNA Library Panels Master Plates -Mouse Thymus from OriGene Technologies
8. Rapid-Screen Arrayed cDNA Library Panels Master Plates -Human Brain (fetal) from OriGene Technologies
9. Rapid-Screen Arrayed cDNA Library Panels Master Plates -Human Lung from OriGene Technologies
10. Rapid-Screen Arrayed cDNA Library Panels Master Plates -Human Colon from OriGene Technologies
11. Rapid-Screen Arrayed cDNA Library Panels Master Plates -Human Spleen from OriGene Technologies
... Analysis Note: Evaluated for its amino acid acceptor ... amino acids Ala, Asp, Gly, Ile, Lys, Pro, ... Tyr. Preparation Unit Definition: One unit will yield ... ml of water (1 cm light path). ...
... use as a carrier in ... Physical form: Solution in 10 ... 1 mM EDTA Preparation Note: ... Concentration: 10 mg/mL ...
... White solid. PACKAGED UNDER INERT GAS. ... polyacrylamide resin with applications similar to those of ... 233156 , and 233155 ) but with ... added to the system. REDUCTACRYL™ Reagent can be ...
... 1,4-Dithiothreitol DTT ... Purity: ≥99% by titration. ... (100 mM, 1 cm, 260 nm): ≤0.500; ... Heavy metals: ≤0.001%. Soluble ...
Biology Products:
(Date:7/18/2020)... (PRWEB) , ... July 16, 2020 , ... ... that demonstrates the effectiveness of the Invictus Medical Neoasis™ active noise control device ... The study reported that the Neoasis™ device attenuated the alarm sounds from patient ...
(Date:7/10/2020)... ... 08, 2020 , ... Overcoming Comparability Issues in Regenerative Medicines ... Wednesday, July 22, 2020 • 1:30 p.m.-3:00 p.m. EDT, https://www.fdanews.com/cellandgenetherapy , ... way to complete one? Will the study comply with all FDA requirements? Understanding ...
(Date:7/4/2020)... ... , ... Aesthetics Biomedical (ABM), a leading aesthetics product development ... the products and treatments developed, but also the dedicated team behind the brands ... built by ABM have received several honors already for 2020, each of which ...
Breaking Biology News(10 mins):
(Date:9/1/2020)... SOUTH RIDING, Va. (PRWEB) , ... September 01, ... ... search firm for life sciences, biotechnology, and diagnostics companies, has announced the placement ... Technologies . Averill will be responsible for leading all financial operations and implementing ...
(Date:8/12/2020)... ... August 11, 2020 , ... ... chain validation engineering firm, is making available for free its new white ... incorporate concurrent transport simulation testing into today’s biologics licensing application (BLA). In ...
(Date:7/31/2020)... ... ... R3 Stem Cell International is now offering patients the opportunity to receive four ... may choose which extremities they would like treated. , Several studies have shown just ... R3 International, umbilical cord tissue is obtained from a lab with a long history ...
(Date:7/31/2020)... ... July 29, 2020 , ... eSource has long been touted ... will cover the history of eSource, the reasons it did not take off as ... to site source, the industry is moving towards capturing data electronically for clinical trials ...
Breaking Biology Technology: