Navigation Links
Rapid-Screen Arrayed cDNA Library Panels Master Plates -Human Colon from OriGene Technologies

ProductsRapid-Screen Arrayed cDNA Library Panels Master Plates -Human Colon from OriGene Technologies
Company OriGene Technologies
Item Rapid-Screen Arrayed cDNA Library Panels Master Plates -Human Colon
Price $925.00
Description The Rapid-Screen cDNA Library Panels were designed for full-length gene cloning and require just three sets of PCRs to identify the desired cDNA clone. The first PCR analysis is performed in a 96-well "Master Plate," where each well contains plasmid DNA from 5,000 clones. Having identified the positive well(s) by gel electrophoresis of the reaction products, the second PCR analysis is carried out in the corresponding 96-well "Sub-Plate(s)," which contains all 5,000 clones from the positive well of the Master Plate arrayed at only 50 clones per well. Since this plate contains glycerol stocks of E. coli instead of plasmid DNA, the cells can be diluted and plated out once a positive well(s) has been identified. Analysis of 96 single colonies by PCR leads to the identification of the positive clone from the Sub-Plate well. To ensure that a clone detected in a specific well in the Master Plate will be represented in the appropriate Sub-Plate, the Sub- Plates were not derived by dilution of individual wells from the Master Plate (a process which may lose specific clones). Instead, the Sub-Plates were generated first and the wells from each Sub-Plate were then pooled to generate the Master Plate. To guarantee that clones from different wells in the Master Plate were each independently-derived, the Sub-Plates were generated with primary transformants that had not been amplified.
Info OriGene TechnologiesOriGene Technologies
6 Taft Court, Suite 100
Rockville, MD 20850
USA

Call OriGene Technologies to buy products (US and Canada only; other locations use numbers below)
USA Canada 1-866-592-4179
Customer Service: 1-888-267-4436 (U.S. only) / 301-340-3188
Fax Number: 301-340-9254
Web Site: http://www.origene.com
NOTE: Price information is approximate list price and actual prices may vary.

Related biology products :

1. Rapid-Screen Arrayed cDNA Library Panels Master Plates -Human Placenta from OriGene Technologies
2. Rapid-Screen Arrayed cDNA Library Panels Master Plates -Human Heart from OriGene Technologies
3. Rapid-Screen Arrayed cDNA Library Panels Master Plates -Mouse Testis from OriGene Technologies
4. Rapid-Screen Arrayed cDNA Library Panels Master Plates -Mouse Brain (adult) from OriGene Technologies
5. Rapid-Screen Arrayed cDNA Library Panels Master Plates -Mouse Embryo (12.5 - day) from OriGene Technologies
6. Rapid-Screen Arrayed cDNA Library Panels Master Plates -Mouse Embryo (19 - day) from OriGene Technologies
7. Rapid-Screen Arrayed cDNA Library Panels Master Plates -Mouse Thymus from OriGene Technologies
8. Rapid-Screen Arrayed cDNA Library Panels Master Plates -Rat Brain (adult) from OriGene Technologies
9. Rapid-Screen Arrayed cDNA Library Panels Master Plates -Human Brain (fetal) from OriGene Technologies
10. Rapid-Screen Arrayed cDNA Library Panels Master Plates -Human Lung from OriGene Technologies
11. Rapid-Screen Arrayed cDNA Library Panels Master Plates -Human Spleen from OriGene Technologies
Goat polyclonal to Nebraska Calf Diarrhea Virus (FITC) ( Abpromise for all tested applications). Antigen: Bovine (Nebraska Calf Diarrhea Virus)....
DNA fragmentation factor & Inhibitor of CAD...
Rabbit polyclonal to Methionine Aminopeptidase 2 ( Abpromise for all tested applications). entrezGeneID: 10988 SwissProtID: P50579...
Phospho-FKHR (Thr24)/FKHRL1 (Thr32) Antibody...
Biology Products:
(Date:7/31/2020)... , ... July 30, 2020 , ... ... (SBIR) Phase II contract awarded by the Joint Science & Technology Office—Chemical and ... project is to develop, optimize, and scale-up a highly efficient mammalian cell culture-based ...
(Date:7/10/2020)... ... July 08, 2020 , ... Overcoming Comparability Issues ... An FDAnews Webinar, Wednesday, July 22, 2020 • 1:30 p.m.-3:00 p.m. EDT, ... the most effective way to complete one? Will the study comply with all ...
(Date:7/1/2020)... ... July 01, 2020 , ... Catalent, a global leader in ... Pharmaceuticals’ packaging facility in Minakuchi, located in the Shiga prefecture of Japan. , ... Kakegawa, the new 60,000-square-foot facility will provide customers with flexible clinical supply solutions, ...
Breaking Biology News(10 mins):
(Date:7/31/2020)... ... July 29, 2020 , ... eSource has long been touted as ... cover the history of eSource, the reasons it did not take off as quickly ... site source, the industry is moving towards capturing data electronically for clinical trials and ...
(Date:7/18/2020)... (PRWEB) , ... July 16, 2020 , ... “We are ... Third Wave Bioactives. “It’s the only technology of its kind on the market and ... of onions with the protective capacity of traditional cultured ingredients, creating a natural way ...
(Date:7/10/2020)... HONG KONG (PRWEB) , ... July 09, 2020 ... ... chemical compound called 1-phenyl-2-thiourea (PTU) is commonly used to suppress pigment formation in ... years, the PolyU research team led by Dr MA has been using the ...
(Date:7/1/2020)... ... 29, 2020 , ... The Interlocal Purchasing System (TIPS), a ... recently named BioFit Engineered Products an Awarded Vendor. Awarded Vendor status ... cafeteria tables, book trucks and carts at discounted pricing without the delay and ...
Breaking Biology Technology: